Transitioning to\na Lower Global Warming Refrigerant,\na Performance Study of R‑513A and HFC-134a in Commercial Chillers

The performance of R-513A and HFC-134a refrigerants is\ncompared\nin two identical chillers operating at the University of Kansas. R-513A\nis a more environmentally friendly refrigerant due to its lower global\nwarming potential that can be used as a retrofit replacement for HFC-134a\nin chillers. This study investigates the performance comparison of\ntransitioning from HFC-134a to R-513A. The chillers have been in operation\nfor two years, and cooling capacity, coefficient of performance, and\nother operating parameters are compared under similar cooling conditions.\nCooling capacities ranged from 100 to 500 kW for both chillers. Overall,\nthe energy consumption and coefficient of performance were statistically\nthe same when operating at the same cooling loads.

Publication Details

Journal
Figshare
Published
2024-12-02
DOI
https://doi.org/10.1021/acs.iecr.4c03586.s001
Primary Topic
Educational Reforms and Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transitioning to\na Lower Global Warming Refrigerant,\na Performance Study of R‑513A and HFC-134a in Commercial Chillers

Figshare
Educational Reforms and Innovations
article

Transitioning to\na Lower Global Warming Refrigerant,\na Performance Study of R‑513A and HFC-134a in Commercial Chillers

article en

Abstract

The performance of R-513A and HFC-134a refrigerants is\ncompared\nin two identical chillers operating at the University of Kansas. R-513A\nis a more environmentally friendly refrigerant due to its lower global\nwarming potential that can be used as a retrofit replacement for HFC-134a\nin chillers. This study investigates the performance comparison of\ntransitioning from HFC-134a to R-513A. The chillers have been in operation\nfor two years, and cooling capacity, coefficient of performance, and\nother operating parameters are compared under similar cooling conditions.\nCooling capacities ranged from 100 to 500 kW for both chillers. Overall,\nthe energy consumption and coefficient of performance were statistically\nthe same when operating at the same cooling loads.

Figshare
Affordable and clean energy
Openalex Percentile: Top 55%
Educational Reforms and Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.