All-in-One PANI@PDA/PVDFSmart Textiles for MultifunctionalBiomonitoring

Smart textiles play a vital role in physiological monitoring, mobile healthcare, and human–machine interface. Multifunctionality remarkably benefits the miniaturization and integration of wearable electronics. Here, we developed a PANI@PDA/PVDF composite textile (PCT)-based multifunctional sensor by combining electrospinning with in situ polymerization. This prepared multifunctional sensor features a wide pressure detection range (0–70 kPa), high sensitivity (10.1 [kPa]<sup>−1</sup>), fast response rate, and excellent stability, which is capable of discerning subtle pulse, respiratory patterns, and limb movement. Furthermore, the PDA anchoring-enabled π–π conjugation effect promises good ammonia sensing performance with a sensitivity of 1.76% ppm<sup>–1</sup> and a response of 320.5% at 200 ppm of NH<sub>3</sub>, demonstrating great potential in distinguishing the biomarker for kidney disease prognosis. This work unravels the possibility for constructing multifunctional biomonitoring devices for multimodal physiological diagnosis.

Publication Details

Journal
Figshare
Published
2025-02-17
DOI
https://doi.org/10.1021/acsaelm.4c02132.s001
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

All-in-One PANI@PDA/PVDFSmart Textiles for MultifunctionalBiomonitoring

Figshare
Diverse Scientific and Economic Studies
article

All-in-One PANI@PDA/PVDFSmart Textiles for MultifunctionalBiomonitoring

article en

Abstract

Smart textiles play a vital role in physiological monitoring, mobile healthcare, and human–machine interface. Multifunctionality remarkably benefits the miniaturization and integration of wearable electronics. Here, we developed a PANI@PDA/PVDF composite textile (PCT)-based multifunctional sensor by combining electrospinning with in situ polymerization. This prepared multifunctional sensor features a wide pressure detection range (0–70 kPa), high sensitivity (10.1 [kPa]<sup>−1</sup>), fast response rate, and excellent stability, which is capable of discerning subtle pulse, respiratory patterns, and limb movement. Furthermore, the PDA anchoring-enabled π–π conjugation effect promises good ammonia sensing performance with a sensitivity of 1.76% ppm<sup>–1</sup> and a response of 320.5% at 200 ppm of NH<sub>3</sub>, demonstrating great potential in distinguishing the biomarker for kidney disease prognosis. This work unravels the possibility for constructing multifunctional biomonitoring devices for multimodal physiological diagnosis.

Figshare
Industry, innovation and infrastructure
Openalex Percentile: Top 46%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.