RADIOLOGICAL EVALUATION OF LEAD APRON INTEGRITY IN FIVE SELECTED HOSPITALS IN ABUJA, NIGERIA

Background: The general consensus is that any exposure to ionising radiation carries a risk. Diagnostic radiology is the largest (87%) contributor to man-made ionising radiation, therefore any economical and socially acceptable means of reducing dose without compromising the diagnostic value of the procedure must be worth implementing. Aim: This study is aimed at evaluating lead apron integrity in five selected Hospitals in Abuja, Nigeria. Methodology: The methodology approach includes the application of a large area beam for transmission measurement with the placement of OSLD before and behind the ten (10) lead aprons to determine the entrance and exit dose as well as the transmission factor. In this study, lead apron consisting of 0.25mm and 0.35mm thickness were examined. Results: The result shows that the transmittance factor of the entrance and exit dose through the lead equivalent aprons is directly proportional to the age of the apron with NHA1 having the highest transmission factor (0.83) and oldest age (16 years). WGH2 has the lowest transfer factor (0.12) and the least age (1 year). Conclusion: Lead aprons loses their attenuation capability over time and should be replace after 15 years at most for effective protection against ionizing radiation.

Institutions

Publication Details

Journal
JRRS
Published
2025-05-16
DOI
https://doi.org/10.82547/jrrs/2021/szcv3165
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RADIOLOGICAL EVALUATION OF LEAD APRON INTEGRITY IN FIVE SELECTED HOSPITALS IN ABUJA, NIGERIA

JRRS
Radiation Dose and Imaging
article

RADIOLOGICAL EVALUATION OF LEAD APRON INTEGRITY IN FIVE SELECTED HOSPITALS IN ABUJA, NIGERIA

article en

Abstract

Background: The general consensus is that any exposure to ionising radiation carries a risk. Diagnostic radiology is the largest (87%) contributor to man-made ionising radiation, therefore any economical and socially acceptable means of reducing dose without compromising the diagnostic value of the procedure must be worth implementing. Aim: This study is aimed at evaluating lead apron integrity in five selected Hospitals in Abuja, Nigeria. Methodology: The methodology approach includes the application of a large area beam for transmission measurement with the placement of OSLD before and behind the ten (10) lead aprons to determine the entrance and exit dose as well as the transmission factor. In this study, lead apron consisting of 0.25mm and 0.35mm thickness were examined. Results: The result shows that the transmittance factor of the entrance and exit dose through the lead equivalent aprons is directly proportional to the age of the apron with NHA1 having the highest transmission factor (0.83) and oldest age (16 years). WGH2 has the lowest transfer factor (0.12) and the least age (1 year). Conclusion: Lead aprons loses their attenuation capability over time and should be replace after 15 years at most for effective protection against ionizing radiation.

JRRS
Nasarawa State University (NG)
Openalex Percentile: Top 41%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

RADIOLOGICAL EVALUATION OF LEAD APRON INTEGRITY IN FIVE SELECTED HOSPITALS IN ABUJA, NIGERIA · JRRS (2025) | TGRS Research Map | TGRS