Experimental Study of The Growth of Ammonium Bisulfate Ash Deposition at Different Wall Temperatures and Heat Transfer Characteristics

\nThe deposition of ammonium bisulfate ash (ABS) is a common occurrence in the flue of a boiler in a power plant. This can result in a reduction in the efficiency of the selective catalytic reduction (SCR) process and the air preheater. To reduce the formation of ABS deposits in flue gas systems, extend the service life of SCR catalysts, and improve the efficiency of heat exchangers, online monitoring technology was employed to observe the formation of ABS deposits in a vertical one-dimensional furnace. The objective of this study is to investigate the formation of ABS deposits on heat transfer surfaces at varying temperatures and their impact on heat transfer characteristics. It was observed that the growth rate of ABS deposition decreased with the increase in wall temperature. At temperatures of 250°C, 300°C, and 350°C, the stable thickness of ABS deposition decreased to 4.09mm, 3.97mm, and 3.84mm, respectively. Moreover, the relative heat flux (RHF) also increases with the increase of wall temperature, from 0.68 at 250°C to 0.78 at 350°C. Consequently, an increase in the surface temperature of the heat transfer medium can effectively reduce the formation of ABS deposits and enhance the efficiency of heat transfer.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-11-27
DOI
https://doi.org/10.1051/e3sconf/202459801002/pdf
Primary Topic
Industrial Gas Emission Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study of The Growth of Ammonium Bisulfate Ash Deposition at Different Wall Temperatures and Heat Transfer Characteristics

Springer Link (Chiba Institute of Technology)
Industrial Gas Emission Control
article

Experimental Study of The Growth of Ammonium Bisulfate Ash Deposition at Different Wall Temperatures and Heat Transfer Characteristics

article en

Abstract

\nThe deposition of ammonium bisulfate ash (ABS) is a common occurrence in the flue of a boiler in a power plant. This can result in a reduction in the efficiency of the selective catalytic reduction (SCR) process and the air preheater. To reduce the formation of ABS deposits in flue gas systems, extend the service life of SCR catalysts, and improve the efficiency of heat exchangers, online monitoring technology was employed to observe the formation of ABS deposits in a vertical one-dimensional furnace. The objective of this study is to investigate the formation of ABS deposits on heat transfer surfaces at varying temperatures and their impact on heat transfer characteristics. It was observed that the growth rate of ABS deposition decreased with the increase in wall temperature. At temperatures of 250°C, 300°C, and 350°C, the stable thickness of ABS deposition decreased to 4.09mm, 3.97mm, and 3.84mm, respectively. Moreover, the relative heat flux (RHF) also increases with the increase of wall temperature, from 0.68 at 250°C to 0.78 at 350°C. Consequently, an increase in the surface temperature of the heat transfer medium can effectively reduce the formation of ABS deposits and enhance the efficiency of heat transfer.\n

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 66%
Industrial Gas Emission Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.