Partial discharges in power transformers

\nTansformers are among the most responsible and expensive elements of the power system, therefore monitoring the technical condition of the transformer is an important and urgent task. One of the signs of aging of insulation in a transformer may be partial discharges (PD), leading to its further failure. The use of monitoring systems based on PD analysis makes it possible to prevent the severe consequences of short circuits in transformers and, as a result, achieve significant economic effects during the operation of controlled high-voltage equipment. The transformer monitoring system based on the partial discharge method is complex and not always effective, because fixed discharges in transformer insulation can be observed for years and do not lead to breakdown, and among the PD it is not always possible to identify the leader's transition to the through phase in time, which creates sufficient conditions for breakdown. In practice, the discharge test is performed using chromatographic analysis of dissolved gases in oil (CADG) or by measuring discharge activity. The article analyzes the effectiveness of PD control methods and the need to develop mathematical models of partial discharges that allow studying the dynamics of the streamer-leader transition in controlled isolation.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-10-25
DOI
https://doi.org/10.1051/e3sconf/202458307001/pdf
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial discharges in power transformers

Springer Link (Chiba Institute of Technology)
Power Transformer Diagnostics and Insulation
article

Partial discharges in power transformers

article en

Abstract

\nTansformers are among the most responsible and expensive elements of the power system, therefore monitoring the technical condition of the transformer is an important and urgent task. One of the signs of aging of insulation in a transformer may be partial discharges (PD), leading to its further failure. The use of monitoring systems based on PD analysis makes it possible to prevent the severe consequences of short circuits in transformers and, as a result, achieve significant economic effects during the operation of controlled high-voltage equipment. The transformer monitoring system based on the partial discharge method is complex and not always effective, because fixed discharges in transformer insulation can be observed for years and do not lead to breakdown, and among the PD it is not always possible to identify the leader's transition to the through phase in time, which creates sufficient conditions for breakdown. In practice, the discharge test is performed using chromatographic analysis of dissolved gases in oil (CADG) or by measuring discharge activity. The article analyzes the effectiveness of PD control methods and the need to develop mathematical models of partial discharges that allow studying the dynamics of the streamer-leader transition in controlled isolation.\n

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 67%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Partial discharges in power transformers · Springer Link (Chiba Institute of Technology) (2024) | TGRS Research Map | TGRS