Automated Calibration\nfor Rapid Optical Spectroscopy\nSensor Development for Online Monitoring

An automated platform has been developed to assist researchers\nin the rapid development of optical spectroscopy sensors to quantify\nspecies from spectral data. This platform performs calibration and\nvalidation measurements simultaneously. Real-time, in situ monitoring\nof complex systems through optical spectroscopy has been shown to\nbe a useful tool; however, building calibration models requires development\ntime, which can be a limiting factor in the case of radiological or\notherwise hazardous systems. While calibration time can be reduced\nthrough optimized design of experiments, this study approached the\nchallenge differently through automation. The ATLAS (Automated Transient\nLearning for Applied Sensors) platform used pneumatic control of stock\nsolutions to cycle flow profiles through desired calibration concentrations\nfor multivariate model construction. Additionally, the transients\nbetween desired concentrations based on flow calculations were used\nas validation measurements to understand model predictive capabilities.\nThis automated approach yielded an incredible 76% reduction in model\ndevelopment time and a 60% reduction in sample volume versus estimated\nmanual sample preparation and static measurements. The ATLAS system\nwas demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho\nrepresenting a use case with significant overlap or interference between\nanalyte signatures and an alternate system containing Pr/Nd/Ni to\ndemonstrate a use case in which broad-band corrosion species signatures\ninterfered with more distinct lanthanide absorbance profiles. Both\nsystems resulted in strong model prediction performance (RMSEP <\n9%). Lastly, ATLAS was demonstrated as a tool to simulate process\nmonitoring scenarios (e.g., column separation) in which models can\nbe further optimized to account for day-to-day changes as necessary\n(e.g., baseline correction). Ultimately, ATLAS offers a vital tool\nto rapidly screen monitoring methods, investigate sensor fusion, and\nexplore more complex systems (i.e., larger numbers of species).

Publication Details

Journal
Figshare
Published
2024-09-19
DOI
https://doi.org/10.1021/acssensors.4c02211.s001
Primary Topic
Digitalization, Law, and Regulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Calibration\nfor Rapid Optical Spectroscopy\nSensor Development for Online Monitoring

Figshare
Digitalization, Law, and Regulation
article

Automated Calibration\nfor Rapid Optical Spectroscopy\nSensor Development for Online Monitoring

article en

Abstract

An automated platform has been developed to assist researchers\nin the rapid development of optical spectroscopy sensors to quantify\nspecies from spectral data. This platform performs calibration and\nvalidation measurements simultaneously. Real-time, in situ monitoring\nof complex systems through optical spectroscopy has been shown to\nbe a useful tool; however, building calibration models requires development\ntime, which can be a limiting factor in the case of radiological or\notherwise hazardous systems. While calibration time can be reduced\nthrough optimized design of experiments, this study approached the\nchallenge differently through automation. The ATLAS (Automated Transient\nLearning for Applied Sensors) platform used pneumatic control of stock\nsolutions to cycle flow profiles through desired calibration concentrations\nfor multivariate model construction. Additionally, the transients\nbetween desired concentrations based on flow calculations were used\nas validation measurements to understand model predictive capabilities.\nThis automated approach yielded an incredible 76% reduction in model\ndevelopment time and a 60% reduction in sample volume versus estimated\nmanual sample preparation and static measurements. The ATLAS system\nwas demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho\nrepresenting a use case with significant overlap or interference between\nanalyte signatures and an alternate system containing Pr/Nd/Ni to\ndemonstrate a use case in which broad-band corrosion species signatures\ninterfered with more distinct lanthanide absorbance profiles. Both\nsystems resulted in strong model prediction performance (RMSEP <\n9%). Lastly, ATLAS was demonstrated as a tool to simulate process\nmonitoring scenarios (e.g., column separation) in which models can\nbe further optimized to account for day-to-day changes as necessary\n(e.g., baseline correction). Ultimately, ATLAS offers a vital tool\nto rapidly screen monitoring methods, investigate sensor fusion, and\nexplore more complex systems (i.e., larger numbers of species).

Figshare
Openalex Percentile: Top 34%
Digitalization, Law, and Regulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.