Optical <sup>14</sup>C Tracing for Biological andPharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based <sup>14</sup>C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR <sup>14</sup>C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level <sup>14</sup>C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample <sup>14</sup>C content by measuring the <sup>14</sup>CO<sub>2</sub> absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of <sup>14</sup>CO<sub>2</sub>. The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10<sup>15</sup>) <sup>14</sup>C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS <sup>14</sup>C sensor to two applications relevant to <sup>14</sup>C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10<sup>–15</sup> Ci) quantitation of sample <sup>14</sup>C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ∼25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO<sub>2</sub> processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through <sup>14</sup>CO<sub>2</sub> sampling scheme. This improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity <sup>14</sup>C tracing in biological, pharmaceutical, and clinical studies.

Publication Details

Journal
Figshare
Published
2025-03-04
DOI
https://doi.org/10.1021/acs.analchem.4c04874.s001
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical 14C Tracing for Biological andPharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Figshare
Spectroscopy and Laser Applications
article

Optical 14C Tracing for Biological andPharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

article en

Abstract

Laser-based <sup>14</sup>C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR <sup>14</sup>C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level <sup>14</sup>C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample <sup>14</sup>C content by measuring the <sup>14</sup>CO<sub>2</sub> absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of <sup>14</sup>CO<sub>2</sub>. The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10<sup>15</sup>) <sup>14</sup>C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS <sup>14</sup>C sensor to two applications relevant to <sup>14</sup>C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10<sup>–15</sup> Ci) quantitation of sample <sup>14</sup>C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ∼25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO<sub>2</sub> processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through <sup>14</sup>CO<sub>2</sub> sampling scheme. This improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity <sup>14</sup>C tracing in biological, pharmaceutical, and clinical studies.

Figshare
Openalex Percentile: Top 60%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optical <sup>14</sup>C Tracing for Biological andPharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy · Figshare (2025) | TGRS Research Map | TGRS