Electric Field Analysis at Triple-Joints and Localized Defects on Different Composite Insulators Designs

Composite insulators have been extensively employed around the world due to their lighter weight, improved performance in harsh environments, and potential lower maintenance costs. However, brittle fracture caused by stress corrosion cracking may occur due to water penetration into metal end fittings during operation, even under lower mechanical loads, possibly leading to a complete failure of the composite insulator. Given that the electric field may play a role in brittle fracture of composite insulators in form of partial discharges, two of the most common existing designs that result in different locations of the triple-joint - interface consisting of metal end-fitting, air, and polymer - are studied. The electric field intensification at the triple-joints is modeled using finite element modeling and validated by analytical calculations. In addition, as another recurrent physical defect in composite insulators, air voids are assessed in different locations of the analyzed composite insulator designs to determine their criticality on brittle fracture mechanism. Results present the optimal design based on the location of the triple-joint in composite insulators, and the most critical locations where air voids may severely contribute to failure modes in the composite insulators.

Institutions

Publication Details

Published
2024-10-06
DOI
https://doi.org/10.1109/ceidp61745.2024.10907400
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric Field Analysis at Triple-Joints and Localized Defects on Different Composite Insulators Designs

High voltage insulation and dielectric phenomena
article

Electric Field Analysis at Triple-Joints and Localized Defects on Different Composite Insulators Designs

article en

Abstract

Composite insulators have been extensively employed around the world due to their lighter weight, improved performance in harsh environments, and potential lower maintenance costs. However, brittle fracture caused by stress corrosion cracking may occur due to water penetration into metal end fittings during operation, even under lower mechanical loads, possibly leading to a complete failure of the composite insulator. Given that the electric field may play a role in brittle fracture of composite insulators in form of partial discharges, two of the most common existing designs that result in different locations of the triple-joint - interface consisting of metal end-fitting, air, and polymer - are studied. The electric field intensification at the triple-joints is modeled using finite element modeling and validated by analytical calculations. In addition, as another recurrent physical defect in composite insulators, air voids are assessed in different locations of the analyzed composite insulator designs to determine their criticality on brittle fracture mechanism. Results present the optimal design based on the location of the triple-joint in composite insulators, and the most critical locations where air voids may severely contribute to failure modes in the composite insulators.

Wichita State University (US)
Openalex Percentile: Top 76%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electric Field Analysis at Triple-Joints and Localized Defects on Different Composite Insulators Designs · (2024) | TGRS Research Map | TGRS