Near-InfraredMobile Cloud OA-ICOS Sensor System forAtmospheric Carbon Dioxide Monitoring

Based on near-infrared off-axis integrated cavity output spectroscopy (OA-ICOS), a portable carbon dioxide (CO<sub>2</sub>) sensor system capable of atmosphere monitoring is proposed by targeting the CO<sub>2</sub> absorption lines at 2.004 μm. To address the comprehensive issues of complex light-adjustment structures, poor sealing, and slow gas replacement, an effective optimization scheme is introduced, combining fluid dynamics to produce a stable optical resonant cavity with an optical path length of 891 m and a physical length of 30 cm. The sensor system boasts a wide dynamic range of 0.011–800 parts per million (ppm), with a limit of detection (LoD) of 11 parts per billion (ppb) at an averaging time of 0.5 s. To address the issues of long monitoring time and cumbersome data supervision, a cloud monitoring system was developed based on a master control module, a cloud server, and a portable monitoring terminal. Field mobile monitoring of urban CO<sub>2</sub> was conducted over a large area in Changchun city, along with a 7-day fixed-point detection on the campus of Jilin University, verifying the reliability and application potential of the mobile CO<sub>2</sub> monitoring system in field applications.

Publication Details

Journal
Figshare
Published
2025-02-13
DOI
https://doi.org/10.1021/acs.analchem.4c05644.s001
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Near-InfraredMobile Cloud OA-ICOS Sensor System forAtmospheric Carbon Dioxide Monitoring

Figshare
Spectroscopy and Laser Applications
article

Near-InfraredMobile Cloud OA-ICOS Sensor System forAtmospheric Carbon Dioxide Monitoring

article en

Abstract

Based on near-infrared off-axis integrated cavity output spectroscopy (OA-ICOS), a portable carbon dioxide (CO<sub>2</sub>) sensor system capable of atmosphere monitoring is proposed by targeting the CO<sub>2</sub> absorption lines at 2.004 μm. To address the comprehensive issues of complex light-adjustment structures, poor sealing, and slow gas replacement, an effective optimization scheme is introduced, combining fluid dynamics to produce a stable optical resonant cavity with an optical path length of 891 m and a physical length of 30 cm. The sensor system boasts a wide dynamic range of 0.011–800 parts per million (ppm), with a limit of detection (LoD) of 11 parts per billion (ppb) at an averaging time of 0.5 s. To address the issues of long monitoring time and cumbersome data supervision, a cloud monitoring system was developed based on a master control module, a cloud server, and a portable monitoring terminal. Field mobile monitoring of urban CO<sub>2</sub> was conducted over a large area in Changchun city, along with a 7-day fixed-point detection on the campus of Jilin University, verifying the reliability and application potential of the mobile CO<sub>2</sub> monitoring system in field applications.

Figshare
Sustainable cities and communities
Openalex Percentile: Top 60%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.