Magnetic NanoparticlesStabilized by Phosphorylcholine-ContainingPolymer for Label-Free C‑Reactive Protein Detection

This research aims to develop a simple yet effective assay for detecting C-reactive protein (CRP), based on magnetic nanoparticles functionalized with a phosphorylcholine-containing polymer. Magnetic nanoparticles stabilized with poly[(methacrylic acid)-<i>ran</i>-(methacryloyloxyethyl phosphorylcholine)] (PMAMPC-MNPs), were prepared by coprecipitation of ferric and ferrous salts in the presence of PMAMPC. Carboxyl groups in the methacrylic acid (MA) repeat units chelate with Fe atoms during MNPs formation, while the methacryloyloxyethyl phosphorylcholine (MPC) repeat units provide specifically binding sites and conjugate with CRP in the presence of Ca<sup>2+</sup>, leading to the aggregation of PMAMPC-MNPs. The PMAMPC-MNPs were characterized by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), transmission electron microscopy (TEM), dynamic light scattering (DLS), thermogravimetric analysis (TGA), and X-ray diffraction (XRD). To determine CRP detection with the naked eye, the precipitation of PMAMPC-MNPs in the presence of CRP and Ca<sup>2+</sup> was monitored without an external magnetic field. Additionally, by taking advantage of the peroxidase-like activity of MNPs, the addition of 3,3′,5,5′-tetramethylbenzidine (TMB) and H<sub>2</sub>O<sub>2</sub> to the supernatant of unbound PMAMPC-MNPs after magnetic separation allows for the colorimetric determination of CRP. This measurement is inversely proportional to the amount of CRP and is detected in an antibody-free system, with a linear range of 1–5 μg/mL and an experimental limit of detection (LOD) of 1.0 μg/mL. Moreover, 3 μg/mL CRP can also be detected in 50% diluted rabbit serum, covering the CRP cutoff level associated with the risk threshold for cardiovascular disease.

Publication Details

Journal
Figshare
Published
2025-03-06
DOI
https://doi.org/10.1021/acsomega.4c10064.s001
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic NanoparticlesStabilized by Phosphorylcholine-ContainingPolymer for Label-Free C‑Reactive Protein Detection

Figshare
Biosensors and Analytical Detection
article

Magnetic NanoparticlesStabilized by Phosphorylcholine-ContainingPolymer for Label-Free C‑Reactive Protein Detection

article en

Abstract

This research aims to develop a simple yet effective assay for detecting C-reactive protein (CRP), based on magnetic nanoparticles functionalized with a phosphorylcholine-containing polymer. Magnetic nanoparticles stabilized with poly[(methacrylic acid)-<i>ran</i>-(methacryloyloxyethyl phosphorylcholine)] (PMAMPC-MNPs), were prepared by coprecipitation of ferric and ferrous salts in the presence of PMAMPC. Carboxyl groups in the methacrylic acid (MA) repeat units chelate with Fe atoms during MNPs formation, while the methacryloyloxyethyl phosphorylcholine (MPC) repeat units provide specifically binding sites and conjugate with CRP in the presence of Ca<sup>2+</sup>, leading to the aggregation of PMAMPC-MNPs. The PMAMPC-MNPs were characterized by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), transmission electron microscopy (TEM), dynamic light scattering (DLS), thermogravimetric analysis (TGA), and X-ray diffraction (XRD). To determine CRP detection with the naked eye, the precipitation of PMAMPC-MNPs in the presence of CRP and Ca<sup>2+</sup> was monitored without an external magnetic field. Additionally, by taking advantage of the peroxidase-like activity of MNPs, the addition of 3,3′,5,5′-tetramethylbenzidine (TMB) and H<sub>2</sub>O<sub>2</sub> to the supernatant of unbound PMAMPC-MNPs after magnetic separation allows for the colorimetric determination of CRP. This measurement is inversely proportional to the amount of CRP and is detected in an antibody-free system, with a linear range of 1–5 μg/mL and an experimental limit of detection (LOD) of 1.0 μg/mL. Moreover, 3 μg/mL CRP can also be detected in 50% diluted rabbit serum, covering the CRP cutoff level associated with the risk threshold for cardiovascular disease.

Figshare
Openalex Percentile: Top 57%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Magnetic NanoparticlesStabilized by Phosphorylcholine-ContainingPolymer for Label-Free C‑Reactive Protein Detection · Figshare (2025) | TGRS Research Map | TGRS