The impact of temporal clustering on long-term energy system models

The field of energy system modelling is experiencing significant development, driven by the urgent need to redesign the national energy systems to achieve carbon neutrality. A growing interest regards long-term energy system models, which enable tracking the pathway and not only the final need for installations. The increase in complexity may easily lead them to face computational limits. Therefore, modelling approaches are required that cluster data to reduce the size of the problem while limiting errors and inaccuracies. This article studies the impact of temporal clustering on the performances of a sector-integrated energy system model, considering the double-layer clustering scheme operating on two distinct temporal scales: intra-year and inter-year. The former is addressed through typical-day clustering (k-means and k-medoids), while the latter introduces multi-year gaps between representative years. This methodology is implemented in the open-source framework oemof , which is customized to the dual clustering approach. The study addresses a sector-integrated energy system, built on the Italian structure, with a multi-vector and multi-sector perspective along the 2020–2050 horizon. The impact is investigated by comparing multiple options with varying number of typical days and multi-year gap, comparing each configuration with a benchmark without clustering. The approach yields coherent representations of the energy system evolution, simultaneously reducing the memory usage down to 4 %. The outcomes show the benefits of balancing the number of representative years with the number of representative days, suggesting that such a trade-off leads to significant computational advantages. Although literature shows that time-series reduction is case-dependent, the double-layer clustering scheme appears promising for application on even more complex models, where a full-hour resolution would be computationally intractable. • Double-layer clustering scheme, applied to inter-year and intra-year temporal scales. • Comparison of clustering configurations in a complex long-term energy system model. • Memory usage reduces down to 4 % of benchmark with minimal differences in total costs. • Trade-off configurations on both clustering scales are most effective. • Low representative periods in inter- or intra-year scale yield large errors in storage capacities.

Institutions

Publication Details

Journal
Applied Energy
Published
2025-07-18
DOI
https://doi.org/10.1016/j.apenergy.2025.126354
Citations
8
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
5.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of temporal clustering on long-term energy system models

8 citations
Applied Energy
Integrated Energy Systems Optimization
5.84
article

The impact of temporal clustering on long-term energy system models

article en
8 citations

Abstract

The field of energy system modelling is experiencing significant development, driven by the urgent need to redesign the national energy systems to achieve carbon neutrality. A growing interest regards long-term energy system models, which enable tracking the pathway and not only the final need for installations. The increase in complexity may easily lead them to face computational limits. Therefore, modelling approaches are required that cluster data to reduce the size of the problem while limiting errors and inaccuracies. This article studies the impact of temporal clustering on the performances of a sector-integrated energy system model, considering the double-layer clustering scheme operating on two distinct temporal scales: intra-year and inter-year. The former is addressed through typical-day clustering (k-means and k-medoids), while the latter introduces multi-year gaps between representative years. This methodology is implemented in the open-source framework oemof , which is customized to the dual clustering approach. The study addresses a sector-integrated energy system, built on the Italian structure, with a multi-vector and multi-sector perspective along the 2020–2050 horizon. The impact is investigated by comparing multiple options with varying number of typical days and multi-year gap, comparing each configuration with a benchmark without clustering. The approach yields coherent representations of the energy system evolution, simultaneously reducing the memory usage down to 4 %. The outcomes show the benefits of balancing the number of representative years with the number of representative days, suggesting that such a trade-off leads to significant computational advantages. Although literature shows that time-series reduction is case-dependent, the double-layer clustering scheme appears promising for application on even more complex models, where a full-hour resolution would be computationally intractable. • Double-layer clustering scheme, applied to inter-year and intra-year temporal scales. • Comparison of clustering configurations in a complex long-term energy system model. • Memory usage reduces down to 4 % of benchmark with minimal differences in total costs. • Trade-off configurations on both clustering scales are most effective. • Low representative periods in inter- or intra-year scale yield large errors in storage capacities.

Applied EnergyVol. 399
University of Insubria (IT), Politecnico di Milano (IT)
Affordable and clean energy
Openalex Percentile: Top 4%
Integrated Energy Systems Optimization
5.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.