Determination of Phosphatidylcholine in Artificial Crude Soybean Oil by Biosensor Based on Horseradish Peroxidase/Choline Oxidase-Modified Glassy Carbon Electrode

A biosensor for the determination of phosphatidylcholine (PC) in artificial crude soybean oil was fabricated by immobilizing horseradish peroxidase (HRP) and choline oxidase (ChOx) onto on a glassy carbon electrode (GCE) modified with multi-walled carbon nanotube (MWCNTs), SnO2 and chitosan (CS). Under the conditions of ChOx and HRP addition each at 2.5 U and pH 7.5, the sensor showed significant electrochemical response to PC. PC concentrations in the range of 10–300 mg/L were linearly correlated with the peak current, and the detection limit was 2 mg/L. Recoveries for spiked samples ranged from 90% to 110% with relative standard deviations (RSDs) less than 4.68%. Good correlation was observed between the results of the biosensor and those of high performance liquid chromatography (HPLC) with a correlation coefficient (r) of 0.992 9. After 14 days of storage, the sensor still retained 98% of its initial current value, indicating its good stability. This study can provide theoretical support for the rapid inspection and control of vegetable oil refining.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.7506/spkx1002-6630-20240508-049
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Phosphatidylcholine in Artificial Crude Soybean Oil by Biosensor Based on Horseradish Peroxidase/Choline Oxidase-Modified Glassy Carbon Electrode

SHILAP Revista de lepidopterología
Electrochemical sensors and biosensors
article

Determination of Phosphatidylcholine in Artificial Crude Soybean Oil by Biosensor Based on Horseradish Peroxidase/Choline Oxidase-Modified Glassy Carbon Electrode

article en

Abstract

A biosensor for the determination of phosphatidylcholine (PC) in artificial crude soybean oil was fabricated by immobilizing horseradish peroxidase (HRP) and choline oxidase (ChOx) onto on a glassy carbon electrode (GCE) modified with multi-walled carbon nanotube (MWCNTs), SnO2 and chitosan (CS). Under the conditions of ChOx and HRP addition each at 2.5 U and pH 7.5, the sensor showed significant electrochemical response to PC. PC concentrations in the range of 10–300 mg/L were linearly correlated with the peak current, and the detection limit was 2 mg/L. Recoveries for spiked samples ranged from 90% to 110% with relative standard deviations (RSDs) less than 4.68%. Good correlation was observed between the results of the biosensor and those of high performance liquid chromatography (HPLC) with a correlation coefficient (r) of 0.992 9. After 14 days of storage, the sensor still retained 98% of its initial current value, indicating its good stability. This study can provide theoretical support for the rapid inspection and control of vegetable oil refining.

SHILAP Revista de lepidopterología
Northeast Agricultural University (CN)
Openalex Percentile: Top 67%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.