MultifunctionalChitosan/Cellulose/Tannic Acid BiocompositeSponge with Excellent Biocompatibility for Rapid Hemostasis

Hemostatic materials should have efficient and rapid hemostasis, good biocompatibility, and nontoxicity. However, common hemostatic sponges often fail due to their weak mechanical strength, low biocompatibility, and slow hemostasis. Herein, we have developed novel and multifunctional chitosan/cellulose/tannic acid (CS/OMCC/TA) biocomposite sponges by a freeze-drying method without adding any chemical cross-linking agents. The water absorption rate of the biocomposite sponge is as high as 4404%, and the blood absorption rate is as high as 5460%. <i>In vitro</i> coagulation tests have shown that the coagulation ability of CS/OMCC/TA biocomposite sponges is significantly better than that of commercial hemostasis materials. DPPH radical scavenging test and antibacterial experiments demonstrated excellent antioxidant properties and inhibitory effects on Staphylococcus aureus and Escherichia coli. Animal experiments showed that CS/OMCC/TA biocomposite sponges could rapidly hemostasize within 185 s and the blood loss was as low as 107 mg. These findings provide biocompatible and rapid hemostatic materials for the daily emergency trauma treatment and surgical hemostasis.

Publication Details

Journal
Figshare
Published
2025-03-07
DOI
https://doi.org/10.1021/acs.biomac.4c01840.s001
Primary Topic
Hemostasis and retained surgical items
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MultifunctionalChitosan/Cellulose/Tannic Acid BiocompositeSponge with Excellent Biocompatibility for Rapid Hemostasis

Figshare
Hemostasis and retained surgical items
article

MultifunctionalChitosan/Cellulose/Tannic Acid BiocompositeSponge with Excellent Biocompatibility for Rapid Hemostasis

article en

Abstract

Hemostatic materials should have efficient and rapid hemostasis, good biocompatibility, and nontoxicity. However, common hemostatic sponges often fail due to their weak mechanical strength, low biocompatibility, and slow hemostasis. Herein, we have developed novel and multifunctional chitosan/cellulose/tannic acid (CS/OMCC/TA) biocomposite sponges by a freeze-drying method without adding any chemical cross-linking agents. The water absorption rate of the biocomposite sponge is as high as 4404%, and the blood absorption rate is as high as 5460%. <i>In vitro</i> coagulation tests have shown that the coagulation ability of CS/OMCC/TA biocomposite sponges is significantly better than that of commercial hemostasis materials. DPPH radical scavenging test and antibacterial experiments demonstrated excellent antioxidant properties and inhibitory effects on Staphylococcus aureus and Escherichia coli. Animal experiments showed that CS/OMCC/TA biocomposite sponges could rapidly hemostasize within 185 s and the blood loss was as low as 107 mg. These findings provide biocompatible and rapid hemostatic materials for the daily emergency trauma treatment and surgical hemostasis.

Figshare
Clean water and sanitation
Openalex Percentile: Top 37%
Hemostasis and retained surgical items
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.