Lightning Protection Technology for Overhead Insulated Lines of 10kV Distribution Network Based on Linear Least Square Positioning Method

The calculation of the series gap distance of the lightning protection device in the 10 kV distribution network is rough, and the positioning error of the lightning strike point may be large, which affects the stability of electricity consumption. Therefore, research on lightning protection technology for overhead insulated lines in 10 kV distribution networks based on linear least squares positioning method is conducted to improve the lightning protection level of insulated lines. By calculating the lightning protection performance parameters of 10 kV distribution network overhead insulated lines, the parameters of the lightning arrester body are determined. The normal probability distribution method is used to determine the series gap distance of the lightning protection device and complete the design. The linear least squares method is used to locate the lightning strike point of the line, and the lightning protection device is fixed under the conductor at the lightning strike point to achieve lightning protection. Experiments have shown that this technology can effectively determine the series gap distance of lightning protection devices, accurately locate the lightning strike point of insulated lines, reduce the uneven voltage distribution coefficient of insulated lines, and improve the lightning resistance level. At different gap distances, 50% of the lightning impulse discharge voltage can be effectively calculated. When the gap distance is 85 mm , the lightning impulse discharge voltage of the lightning protection device is close to the standard value, and the lightning protection effect is the best. The positioning results of this technology are close to the actual lightning strike point, with high accuracy and strong adaptability. After application, the uneven coefficient of voltage distribution is less than 1.5 , which is better than the situation where it was always higher than 2 before application, and improves the lightning protection effect of the line.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.6180/jase.202510_28(10).0003
Primary Topic
Applied Advanced Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightning Protection Technology for Overhead Insulated Lines of 10kV Distribution Network Based on Linear Least Square Positioning Method

SHILAP Revista de lepidopterología
Applied Advanced Technologies
article

Lightning Protection Technology for Overhead Insulated Lines of 10kV Distribution Network Based on Linear Least Square Positioning Method

article en

Abstract

The calculation of the series gap distance of the lightning protection device in the 10 kV distribution network is rough, and the positioning error of the lightning strike point may be large, which affects the stability of electricity consumption. Therefore, research on lightning protection technology for overhead insulated lines in 10 kV distribution networks based on linear least squares positioning method is conducted to improve the lightning protection level of insulated lines. By calculating the lightning protection performance parameters of 10 kV distribution network overhead insulated lines, the parameters of the lightning arrester body are determined. The normal probability distribution method is used to determine the series gap distance of the lightning protection device and complete the design. The linear least squares method is used to locate the lightning strike point of the line, and the lightning protection device is fixed under the conductor at the lightning strike point to achieve lightning protection. Experiments have shown that this technology can effectively determine the series gap distance of lightning protection devices, accurately locate the lightning strike point of insulated lines, reduce the uneven voltage distribution coefficient of insulated lines, and improve the lightning resistance level. At different gap distances, 50% of the lightning impulse discharge voltage can be effectively calculated. When the gap distance is 85 mm , the lightning impulse discharge voltage of the lightning protection device is close to the standard value, and the lightning protection effect is the best. The positioning results of this technology are close to the actual lightning strike point, with high accuracy and strong adaptability. After application, the uneven coefficient of voltage distribution is less than 1.5 , which is better than the situation where it was always higher than 2 before application, and improves the lightning protection effect of the line.

SHILAP Revista de lepidopterología
China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 44%
Applied Advanced Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.