Energy Management System in Bidirectional DC-DC Converter for Microgrid

In microgrids and energy storage systems that use synchronised power delivery and operationalstability, DC-DC converters are crucial components. This study proposes a closed-loop proportionalintegral (PI) based energy management control technique to assess and solve unstable DC link voltageproblems. In grid-connected mode, battery units and a hybrid energy storage system (HESS), such as asuper-capacitor (SC), are charged by separate hybrid energy resources, such as solar and wind. Theprimary goal of this effort is to supply the grid with energy storage units (supercapacitor and battery) inthe event that solar or wind energy supplies are unavailable. To meet the stability requirement, wind andsolar power generation is first controlled by the energy management control. In order to increase systemflexibility and compatibility with various PV cell and wind energy sources, the MPPT technique has beentaken into consideration. The maximum power was effectively tracked by the suggested system, and theincremental conductance (IC) technique based on galactic swarm optimisation (GSO) is used to assess thedata. GSO should be used in MPPT to obtain a high convergence rate and less steady-state oscillation. TheMATLAB/Simulink platform is used to implement the entire project, and the suggested algorithm'sperformance is compared to that of the current ones.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-11
DOI
https://doi.org/10.5281/zenodo.16794448
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy Management System in Bidirectional DC-DC Converter for Microgrid

Zenodo (CERN European Organization for Nuclear Research)
Microgrid Control and Optimization
article

Energy Management System in Bidirectional DC-DC Converter for Microgrid

article en

Abstract

In microgrids and energy storage systems that use synchronised power delivery and operationalstability, DC-DC converters are crucial components. This study proposes a closed-loop proportionalintegral (PI) based energy management control technique to assess and solve unstable DC link voltageproblems. In grid-connected mode, battery units and a hybrid energy storage system (HESS), such as asuper-capacitor (SC), are charged by separate hybrid energy resources, such as solar and wind. Theprimary goal of this effort is to supply the grid with energy storage units (supercapacitor and battery) inthe event that solar or wind energy supplies are unavailable. To meet the stability requirement, wind andsolar power generation is first controlled by the energy management control. In order to increase systemflexibility and compatibility with various PV cell and wind energy sources, the MPPT technique has beentaken into consideration. The maximum power was effectively tracked by the suggested system, and theincremental conductance (IC) technique based on galactic swarm optimisation (GSO) is used to assess thedata. GSO should be used in MPPT to obtain a high convergence rate and less steady-state oscillation. TheMATLAB/Simulink platform is used to implement the entire project, and the suggested algorithm'sperformance is compared to that of the current ones.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 47%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.