A SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION OF PANTAPRAZOLE IN BULK AND MARKETED FORMULATION

Pantaprazole was estimated using a straightforward, sensitive, and selective UV approach that was devised and verified. The technique was developed using UV spectrometry; the optimal concentration was 10µg/ml, the absorbance was 0.449, and the λmax was reached at 292nm with solvent water: ethanol (8:2 V/V). The linearity range of the test technique was 0.5 µg/ml to 16 µg/ml, which had an R2 value of 0.999. It was discovered that the accuracy % assay 98.64-99.96%. The results indicated that the intraday precision and interday precision % RSD values were found in between 0.32 -0.52. The developed method's LOD and LOQ were 0.15µg/ml and 0.44 µg/ml respectively. The robustness results were found to be 99.72%-101.78% for wavelength variation and organic phase change.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-30
DOI
https://doi.org/10.5281/zenodo.15774782
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION OF PANTAPRAZOLE IN BULK AND MARKETED FORMULATION

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

A SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION OF PANTAPRAZOLE IN BULK AND MARKETED FORMULATION

article en

Abstract

Pantaprazole was estimated using a straightforward, sensitive, and selective UV approach that was devised and verified. The technique was developed using UV spectrometry; the optimal concentration was 10µg/ml, the absorbance was 0.449, and the λmax was reached at 292nm with solvent water: ethanol (8:2 V/V). The linearity range of the test technique was 0.5 µg/ml to 16 µg/ml, which had an R2 value of 0.999. It was discovered that the accuracy % assay 98.64-99.96%. The results indicated that the intraday precision and interday precision % RSD values were found in between 0.32 -0.52. The developed method's LOD and LOQ were 0.15µg/ml and 0.44 µg/ml respectively. The robustness results were found to be 99.72%-101.78% for wavelength variation and organic phase change.

Zenodo (CERN European Organization for Nuclear Research)
Dr. Babasaheb Ambedkar Technological University (IN), Bombay College of Pharmacy (IN)
Openalex Percentile: Top 54%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.