Computational Fluid-Structure Interaction of Polyurethane-based Vascular Graft

This work described the numerical fluid-structure interaction of the polyurethane-based vascular graft and the femoral artery results. Polyurethanes were synthetized from a mixture of polyethylene glycol (PEG), polycaprolactone diol (PCL) and Pentaerythritol (PE). Blood was modeled as a laminar, incompressible, non-Newtonian, and isothermal flow. In contrast, each conduit's wall mechanics was modeled through a hyperelastic constitutive model assuming isotropic, homogenous, and incompressible material. Sinusoidal blood pressure was applied to study the velocity, von Mises stress, total displacement, and shear stress of each vessel. The data suggested that PU-based grafts with a composition of 45-45-10 and 46.3-46.3-7.5 PEG/PCL/PE could enhance the compliance response and reduced the mechanical mismatch between the native blood vessel and the prosthesis. However, further analysis with more complex geometries should be addressed to identify flow disturbance and the stress distribution at the anastomosis site.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-03-16
DOI
https://doi.org/10.5281/zenodo.15036474
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational Fluid-Structure Interaction of Polyurethane-based Vascular Graft

Zenodo (CERN European Organization for Nuclear Research)
Aortic aneurysm repair treatments
article

Computational Fluid-Structure Interaction of Polyurethane-based Vascular Graft

article en

Abstract

This work described the numerical fluid-structure interaction of the polyurethane-based vascular graft and the femoral artery results. Polyurethanes were synthetized from a mixture of polyethylene glycol (PEG), polycaprolactone diol (PCL) and Pentaerythritol (PE). Blood was modeled as a laminar, incompressible, non-Newtonian, and isothermal flow. In contrast, each conduit's wall mechanics was modeled through a hyperelastic constitutive model assuming isotropic, homogenous, and incompressible material. Sinusoidal blood pressure was applied to study the velocity, von Mises stress, total displacement, and shear stress of each vessel. The data suggested that PU-based grafts with a composition of 45-45-10 and 46.3-46.3-7.5 PEG/PCL/PE could enhance the compliance response and reduced the mechanical mismatch between the native blood vessel and the prosthesis. However, further analysis with more complex geometries should be addressed to identify flow disturbance and the stress distribution at the anastomosis site.

Zenodo (CERN European Organization for Nuclear Research)
Universidad de La Sabana (CO)
Openalex Percentile: Top 38%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.