Colorimetry-based quantification of protein droplets using "ImageJ"

The objective of this study is to analyze protein concentration on a colorimetric basis by utilizing the openly accessible 'ImageJ' software. We herein report the successful measurement of protein concentration on a parafilm surface, following the application of Bradford reagent and subsequent photography with a smartphone, followed by analysis using the ImageJ software. Ovalbumin (OVA) and bovine serum albumin (BSA) were dissolved in phosphate buffered saline (PBS) and used as standards. The results demonstrated a linear correlation between integrated density and the actual weight of the standard, with R² values of 0.9908 for OVA samples in the range of 0-1.5 mg/ml and 0.9781 for BSA in the range of 0.25-1.5 mg/ml. The straightforward nature of the experiments and analyses makes the study we present here an invaluable resource for researchers and students who are constrained by equipment limitations, such as the lack of access to spectrophotometers.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-30
DOI
https://doi.org/10.5281/zenodo.14821850
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Colorimetry-based quantification of protein droplets using "ImageJ"

Zenodo (CERN European Organization for Nuclear Research)
Biosensors and Analytical Detection
article

Colorimetry-based quantification of protein droplets using "ImageJ"

article en

Abstract

The objective of this study is to analyze protein concentration on a colorimetric basis by utilizing the openly accessible 'ImageJ' software. We herein report the successful measurement of protein concentration on a parafilm surface, following the application of Bradford reagent and subsequent photography with a smartphone, followed by analysis using the ImageJ software. Ovalbumin (OVA) and bovine serum albumin (BSA) were dissolved in phosphate buffered saline (PBS) and used as standards. The results demonstrated a linear correlation between integrated density and the actual weight of the standard, with R² values of 0.9908 for OVA samples in the range of 0-1.5 mg/ml and 0.9781 for BSA in the range of 0.25-1.5 mg/ml. The straightforward nature of the experiments and analyses makes the study we present here an invaluable resource for researchers and students who are constrained by equipment limitations, such as the lack of access to spectrophotometers.

Zenodo (CERN European Organization for Nuclear Research)
University of Mataram (ID)
Openalex Percentile: Top 69%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.