Abutment-implant intermovement and corrosion. How the cone angle affects implant performance. An introduction to implant abutment connection classification, and the need to leave the platform switching concept behind and move forward

Stress shielding and Titanium corrosion are the main issues that stand behind all titanium implants. Current concepts of the biocompatibility are mostly limited to the surface of the used material, rather than the stiffness or other mechanical criteria. The hub and shaft region of the dental implants had many regions. The most important region is the cone region. Cone angle affects the mechanical response of the implant and the resultant corrosion. Fretting corrosion remain the main issue in metallic hardware. In this introductory paper, we had represented 6 models to assess most of the current implant systems depending on the cone angle. The results show clearly the well-approved clinical issues especially platform switching concept. More models are needed to discern the complete picture.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-23
DOI
https://doi.org/10.5281/zenodo.15717428
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abutment-implant intermovement and corrosion. How the cone angle affects implant performance. An introduction to implant abutment connection classification, and the need to leave the platform switching concept behind and move forward

Zenodo (CERN European Organization for Nuclear Research)
Dental Implant Techniques and Outcomes
article

Abutment-implant intermovement and corrosion. How the cone angle affects implant performance. An introduction to implant abutment connection classification, and the need to leave the platform switching concept behind and move forward

article en

Abstract

Stress shielding and Titanium corrosion are the main issues that stand behind all titanium implants. Current concepts of the biocompatibility are mostly limited to the surface of the used material, rather than the stiffness or other mechanical criteria. The hub and shaft region of the dental implants had many regions. The most important region is the cone region. Cone angle affects the mechanical response of the implant and the resultant corrosion. Fretting corrosion remain the main issue in metallic hardware. In this introductory paper, we had represented 6 models to assess most of the current implant systems depending on the cone angle. The results show clearly the well-approved clinical issues especially platform switching concept. More models are needed to discern the complete picture.

Zenodo (CERN European Organization for Nuclear Research)
University Teaching Hospital (ZM)
Openalex Percentile: Top 41%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Abutment-implant intermovement and corrosion. How the cone angle affects implant performance. An introduction to implant abutment connection classification, and the need to leave the platform switching concept behind and move forward · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS