EFFICIENCY CHALLENGES AND PERFORMANCE OPTIMIZATION OF LOW-POWER PUMP MOTORS IN THERMAL POWER PLANTS

this study investigates the operational challenges associated with low-power pump motors in thermal power plant auxiliary systems. Through experimental measurements and computational analysis, we identified significant performance limitations including overheating issues, efficiency losses, and premature failure under variable load conditions. Testing was conducted on 30 pump units (5-75 kW) across three different thermal power plants over a 14-month period. Results demonstrate that optimized motor cooling designs combined with variable frequency drives can increase operational efficiency by 17.3% while extending service life by approximately 2.4 times. Implementation of the proposed enhanced monitoring system reduced unexpected failures by 62% during the trial period. These findings provide valuable insights for improving the reliability and efficiency of auxiliary pump systems in thermal power generation facilities.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-05
DOI
https://doi.org/10.5281/zenodo.15334167
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EFFICIENCY CHALLENGES AND PERFORMANCE OPTIMIZATION OF LOW-POWER PUMP MOTORS IN THERMAL POWER PLANTS

Zenodo (CERN European Organization for Nuclear Research)
Water Systems and Optimization
article

EFFICIENCY CHALLENGES AND PERFORMANCE OPTIMIZATION OF LOW-POWER PUMP MOTORS IN THERMAL POWER PLANTS

article en

Abstract

this study investigates the operational challenges associated with low-power pump motors in thermal power plant auxiliary systems. Through experimental measurements and computational analysis, we identified significant performance limitations including overheating issues, efficiency losses, and premature failure under variable load conditions. Testing was conducted on 30 pump units (5-75 kW) across three different thermal power plants over a 14-month period. Results demonstrate that optimized motor cooling designs combined with variable frequency drives can increase operational efficiency by 17.3% while extending service life by approximately 2.4 times. Implementation of the proposed enhanced monitoring system reduced unexpected failures by 62% during the trial period. These findings provide valuable insights for improving the reliability and efficiency of auxiliary pump systems in thermal power generation facilities.

Zenodo (CERN European Organization for Nuclear Research)
Namangan Engineering Pedagogical Institute (UZ)
Affordable and clean energy
Openalex Percentile: Top 56%
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.