A Clinical and Radiological Comparative Evaluation of Osseodensification Technique and Rotary Bone Expansion Technique for Implant Placement in Low-Density Bone: A 16 Weeks Prospective Randomized Controlled Trial

Background: Dental implants are highly effective for teeth replacement, with stability being crucial for success. Stability, defined by the absence of clinical mobility, includes primary and secondary stability. Primary stability is biomechanical, influenced by bone quality, implant design, surgical technique, and insertion torque. Secondary stability, a biological phenomenon, indicates osseointegration, the direct connection between bone and implant. Resonance Frequency Analysis (RFA) measures stability, recorded as the Implant Stability Quotient (ISQ) on a scale from 1 to 100, with higher values indicating greater stability. Techniques to enhance primary stability, especially in low-density bone, include bi-cortical fixation, under-preparation of the implant bed, osteotomes, and a new method called osseodensification, which increases bone density and improves stability. Methods: Twenty-two single edentulous sites were selected for dental implant placement and divided into two groups of 11. Group A used the osseodensification technique, while Group B used rotary bone expanders. ISQ was recorded at 2, 4, 6, 8, 12, and 16 weeks, and IT and crestal bone levels were evaluated at baseline and 16 weeks. Result: At baseline, Group A had significantly higher ISQ values than Group B. At 2 and 4 weeks, the ISQ difference was non-significant. Subsequently, Group B had higher ISQ values, but the difference remained non-significant. Insertion torque and crestal bone loss differences were also statistically non-significant between the groups. Conclusion: Both osseodensification and rotary bone expander techniques showed statistically non-significant differences in ISQ, IT, and crestal bone loss, indicating equal efficacy for implant osseointegration.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-22
DOI
https://doi.org/10.5281/zenodo.14910958
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Clinical and Radiological Comparative Evaluation of Osseodensification Technique and Rotary Bone Expansion Technique for Implant Placement in Low-Density Bone: A 16 Weeks Prospective Randomized Controlled Trial

Zenodo (CERN European Organization for Nuclear Research)
Dental Implant Techniques and Outcomes
article

A Clinical and Radiological Comparative Evaluation of Osseodensification Technique and Rotary Bone Expansion Technique for Implant Placement in Low-Density Bone: A 16 Weeks Prospective Randomized Controlled Trial

article en

Abstract

Background: Dental implants are highly effective for teeth replacement, with stability being crucial for success. Stability, defined by the absence of clinical mobility, includes primary and secondary stability. Primary stability is biomechanical, influenced by bone quality, implant design, surgical technique, and insertion torque. Secondary stability, a biological phenomenon, indicates osseointegration, the direct connection between bone and implant. Resonance Frequency Analysis (RFA) measures stability, recorded as the Implant Stability Quotient (ISQ) on a scale from 1 to 100, with higher values indicating greater stability. Techniques to enhance primary stability, especially in low-density bone, include bi-cortical fixation, under-preparation of the implant bed, osteotomes, and a new method called osseodensification, which increases bone density and improves stability. Methods: Twenty-two single edentulous sites were selected for dental implant placement and divided into two groups of 11. Group A used the osseodensification technique, while Group B used rotary bone expanders. ISQ was recorded at 2, 4, 6, 8, 12, and 16 weeks, and IT and crestal bone levels were evaluated at baseline and 16 weeks. Result: At baseline, Group A had significantly higher ISQ values than Group B. At 2 and 4 weeks, the ISQ difference was non-significant. Subsequently, Group B had higher ISQ values, but the difference remained non-significant. Insertion torque and crestal bone loss differences were also statistically non-significant between the groups. Conclusion: Both osseodensification and rotary bone expander techniques showed statistically non-significant differences in ISQ, IT, and crestal bone loss, indicating equal efficacy for implant osseointegration.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 41%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Clinical and Radiological Comparative Evaluation of Osseodensification Technique and Rotary Bone Expansion Technique for Implant Placement in Low-Density Bone: A 16 Weeks Prospective Randomized Controlled Trial · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS