Heat Transfer Enhancement in Tube-in-Tube Heat Exchanger Using Twisted Tape Inserts

This study investigates the enhancement of heat transfer in a tube-in-tube heat exchanger using twisted tape inserts. Twisted tape is a passive technique that induces turbulence and swirl flow, thereby increasing the heat transfer coefficient. The experimental study was conducted on a fabricated copper (inner) and mild steel (outer) heat exchanger operating in both parallel and counter flow configurations. Data were collected for various flow rates with and without twisted tape inserts. Calculations were based on the Log Mean Temperature Difference (LMTD) and Effectiveness-NTU methods. The performance was evaluated in terms of Nusselt number, Reynolds number, heat transfer rate, and effectiveness. Comparative analysis revealed significant improvements in heat transfer with twisted tape, particularly under counter flow. This research presents a comprehensive analysis with supporting literature and simulation data for optimized heat exchanger design.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-17
DOI
https://doi.org/10.5281/zenodo.15907757
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Transfer Enhancement in Tube-in-Tube Heat Exchanger Using Twisted Tape Inserts

Zenodo (CERN European Organization for Nuclear Research)
Heat Transfer and Optimization
article

Heat Transfer Enhancement in Tube-in-Tube Heat Exchanger Using Twisted Tape Inserts

article en

Abstract

This study investigates the enhancement of heat transfer in a tube-in-tube heat exchanger using twisted tape inserts. Twisted tape is a passive technique that induces turbulence and swirl flow, thereby increasing the heat transfer coefficient. The experimental study was conducted on a fabricated copper (inner) and mild steel (outer) heat exchanger operating in both parallel and counter flow configurations. Data were collected for various flow rates with and without twisted tape inserts. Calculations were based on the Log Mean Temperature Difference (LMTD) and Effectiveness-NTU methods. The performance was evaluated in terms of Nusselt number, Reynolds number, heat transfer rate, and effectiveness. Comparative analysis revealed significant improvements in heat transfer with twisted tape, particularly under counter flow. This research presents a comprehensive analysis with supporting literature and simulation data for optimized heat exchanger design.

Zenodo (CERN European Organization for Nuclear Research)
Yeovil College (GB)
Affordable and clean energy
Openalex Percentile: Top 56%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.