Seismic Retrofitting of Reinforced Concrete Structures: A Comparative

One of the main goals of retrofitting reinforced concrete (RC) structures is to enhance their safety against natural disasters like earthquakes. A significant number of RC buildings in Canada were constructed several decades ago and may be vulnerable to earthquakes due to the absence of modern design considerations. Therefore, seismic retrofitting of RC buildings is essential to minimize earthquake damage. This study compares two of the most popular techniques used for retrofitting such structures. A six-story RC building located in a high-seismicity zone is retrofitted using a base isolator and a tuned mass damper. The retrofitting systems are designed using routine methods, and their ability to reduce earthquake damage is evaluated. Buildings upgraded with two different retrofitting systems are modeled in the OpenSees software package and subjected to several seismic events. According to the results, the routine methods used for designing the optimal linear TMD and base isolation may not be sufficient to ensure highly efficient performance, as their effectiveness depends on the intensity of seismic excitation.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-28
DOI
https://doi.org/10.5281/zenodo.15044299
Citations
1
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Retrofitting of Reinforced Concrete Structures: A Comparative

1 citations
Zenodo (CERN European Organization for Nuclear Research)
Seismic Performance and Analysis
0.95
article

Seismic Retrofitting of Reinforced Concrete Structures: A Comparative

article en
1 citations

Abstract

One of the main goals of retrofitting reinforced concrete (RC) structures is to enhance their safety against natural disasters like earthquakes. A significant number of RC buildings in Canada were constructed several decades ago and may be vulnerable to earthquakes due to the absence of modern design considerations. Therefore, seismic retrofitting of RC buildings is essential to minimize earthquake damage. This study compares two of the most popular techniques used for retrofitting such structures. A six-story RC building located in a high-seismicity zone is retrofitted using a base isolator and a tuned mass damper. The retrofitting systems are designed using routine methods, and their ability to reduce earthquake damage is evaluated. Buildings upgraded with two different retrofitting systems are modeled in the OpenSees software package and subjected to several seismic events. According to the results, the routine methods used for designing the optimal linear TMD and base isolation may not be sufficient to ensure highly efficient performance, as their effectiveness depends on the intensity of seismic excitation.

Zenodo (CERN European Organization for Nuclear Research)
Sustainable cities and communities
Openalex Percentile: Top 19%
Seismic Performance and Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Seismic Retrofitting of Reinforced Concrete Structures: A Comparative · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS