Fragility Assessment of Adjacent Buildings Coupled with Metallic Shear Dampers under Seismic Pounding Effects

Seismic pounding between adjacent buildings often exacerbates structural damage during earthquakes. This study evaluates the efficacy of metallic shear dampers in mitigating pounding effects and improving the seismic fragility of adjacent structures. A nonlinear finite element model of two adjacent mid-rise steel buildings (5- and 8-story) coupled with metallic shear dampers is developed in Abaqus. The dampers, modeled with a bilinear hysteresis law, are subjected to 20 scaled from the FEMA P-695 far-field suite. Fragility curves are derived for four damage states (slight: 0.5% drift; moderate: 1.0%; extensive: 2.0%; complete: 4.0%) and compared to uncoupled (bare) buildings. Results demonstrate that the dampers reduce peak pounding forces by 38–47% and limit maximum inter-story drifts by 25–32% across all seismic intensities. Furthermore, the coupled system reduces the probability of exceeding moderate damage by 46% and lowers collapse vulnerability by 55%. These findings highlight the coupling system’s robustness in minimizing seismic fragility and pounding risks, providing actionable insights for retrofitting adjacent buildings in earthquake-prone regions.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-03-17
DOI
https://doi.org/10.5281/zenodo.14871150
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fragility Assessment of Adjacent Buildings Coupled with Metallic Shear Dampers under Seismic Pounding Effects

Zenodo (CERN European Organization for Nuclear Research)
Seismic Performance and Analysis
article

Fragility Assessment of Adjacent Buildings Coupled with Metallic Shear Dampers under Seismic Pounding Effects

article en

Abstract

Seismic pounding between adjacent buildings often exacerbates structural damage during earthquakes. This study evaluates the efficacy of metallic shear dampers in mitigating pounding effects and improving the seismic fragility of adjacent structures. A nonlinear finite element model of two adjacent mid-rise steel buildings (5- and 8-story) coupled with metallic shear dampers is developed in Abaqus. The dampers, modeled with a bilinear hysteresis law, are subjected to 20 scaled from the FEMA P-695 far-field suite. Fragility curves are derived for four damage states (slight: 0.5% drift; moderate: 1.0%; extensive: 2.0%; complete: 4.0%) and compared to uncoupled (bare) buildings. Results demonstrate that the dampers reduce peak pounding forces by 38–47% and limit maximum inter-story drifts by 25–32% across all seismic intensities. Furthermore, the coupled system reduces the probability of exceeding moderate damage by 46% and lowers collapse vulnerability by 55%. These findings highlight the coupling system’s robustness in minimizing seismic fragility and pounding risks, providing actionable insights for retrofitting adjacent buildings in earthquake-prone regions.

Zenodo (CERN European Organization for Nuclear Research)
Sichuan University (CN), Delta University for Science and Technology (EG)
Sustainable cities and communities
Openalex Percentile: Top 56%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.