Stereotactic Body Radiotherapy for Lung Cancer: Insights from an Institutional CyberKnife Study

This retrospective study aimed to evaluate the treatment plans and analyse the dosimetric parameters for stereotactic body radiotherapy (SBRT) using the CyberKnife® system in patients with inoperable primary or metastatic lung cancer. Ten lung cancer patients treated with SBRT using the CyberKnife® were included in the study. Treatment plans were designed using the Precision 3.3.1.2 treatment planning system, with optimization performed using the Monte Carlo algorithm. Two tracking methods were employed: fiducial markers with Synchrony® in five cases and direct tumor visualization using Xsight® Lung in the remaining five cases. Patient-specific quality assurance (QA) was conducted using SRS MapCHECK® and StereoPHAN™ phantom, with gamma analysis performed using 2%/2 mm criteria and a 10% threshold.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-03-08
DOI
https://doi.org/10.5281/zenodo.15155230
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stereotactic Body Radiotherapy for Lung Cancer: Insights from an Institutional CyberKnife Study

Zenodo (CERN European Organization for Nuclear Research)
Advanced Radiotherapy Techniques
article

Stereotactic Body Radiotherapy for Lung Cancer: Insights from an Institutional CyberKnife Study

article en

Abstract

This retrospective study aimed to evaluate the treatment plans and analyse the dosimetric parameters for stereotactic body radiotherapy (SBRT) using the CyberKnife® system in patients with inoperable primary or metastatic lung cancer. Ten lung cancer patients treated with SBRT using the CyberKnife® were included in the study. Treatment plans were designed using the Precision 3.3.1.2 treatment planning system, with optimization performed using the Monte Carlo algorithm. Two tracking methods were employed: fiducial markers with Synchrony® in five cases and direct tumor visualization using Xsight® Lung in the remaining five cases. Patient-specific quality assurance (QA) was conducted using SRS MapCHECK® and StereoPHAN™ phantom, with gamma analysis performed using 2%/2 mm criteria and a 10% threshold.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 45%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.