Experimental Validation of Correction Factors for In Situ H-Field Measurements below 2 MHz

A large number of devices cannot be tested in standard electromagnetic compatibility laboratories due to size, power or safety-related constraints. In these cases, the only viable alternative is the in situ approach. The reference standard for in situ testing, CISPR 11, proposes to evaluate the equipment’s emissions in the 150 kHz to 30 MHz range through the measurement of the magnetic field at a 30 m distance. However, at such conditions, the said emissions are barely discernible from ambient noise and sometimes ensuring such fixed measuring distances is not even possible due to limitations of the test site. Emerging standards projects, e.g., CISPR 37, are consideringsetting the reference distance to 10 m while allowing measures at distances from 3 m to 30 m through the application of specific conversion factors to achieve a result that is comparable to the applicable disturbance limits. In this work, the corresponding magnetic field conversion factors are experimentally studied and validated from the in situ standpoint. Results obtained show an excellent match with the proposal in the latest CISPR 37 draft in the frequency range from 150 kHz to 2 MHz.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-09-18
DOI
https://doi.org/10.5281/zenodo.13786553
Primary Topic
Electromagnetic Compatibility and Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Validation of Correction Factors for In Situ H-Field Measurements below 2 MHz

Zenodo (CERN European Organization for Nuclear Research)
Electromagnetic Compatibility and Measurements
article

Experimental Validation of Correction Factors for In Situ H-Field Measurements below 2 MHz

article en

Abstract

A large number of devices cannot be tested in standard electromagnetic compatibility laboratories due to size, power or safety-related constraints. In these cases, the only viable alternative is the in situ approach. The reference standard for in situ testing, CISPR 11, proposes to evaluate the equipment’s emissions in the 150 kHz to 30 MHz range through the measurement of the magnetic field at a 30 m distance. However, at such conditions, the said emissions are barely discernible from ambient noise and sometimes ensuring such fixed measuring distances is not even possible due to limitations of the test site. Emerging standards projects, e.g., CISPR 37, are consideringsetting the reference distance to 10 m while allowing measures at distances from 3 m to 30 m through the application of specific conversion factors to achieve a result that is comparable to the applicable disturbance limits. In this work, the corresponding magnetic field conversion factors are experimentally studied and validated from the in situ standpoint. Results obtained show an excellent match with the proposal in the latest CISPR 37 draft in the frequency range from 150 kHz to 2 MHz.

Zenodo (CERN European Organization for Nuclear Research)
Fuji Electric (Japan) (JP), Research Institute for Electromagnetic Materials (JP), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 68%
Electromagnetic Compatibility and Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Validation of Correction Factors for In Situ H-Field Measurements below 2 MHz · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS