Ventilator pressure prediction using recurrent neural network

This paper presents a recurrent neural network approach to simulating mechanical ventilator pressure. The traditional mechanical ventilator has a control pressure that is monitored by a medical practitioner and can behave incorrectly if the proper pressure is not applied. This paper takes advantage of recent research and develops a simulator based on a deep sequence model to predict airway pressure in the respiratory circuit during the inspiratory phase of a breath given a time series of control parameters and lung attributes. This method demonstrates the effectiveness of neural network-based controllers in tracking pressure wave forms significantly better than the current industry standard and provides insights into the development of effective and robust pressure-controlled mechanical ventilators. The paper will measure as the mean absolute error between the predicted and actual pressures during the inspiratory phase of each breath.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-04
DOI
https://doi.org/10.5281/zenodo.14277317
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventilator pressure prediction using recurrent neural network

Zenodo (CERN European Organization for Nuclear Research)
Respiratory Support and Mechanisms
article

Ventilator pressure prediction using recurrent neural network

article en

Abstract

This paper presents a recurrent neural network approach to simulating mechanical ventilator pressure. The traditional mechanical ventilator has a control pressure that is monitored by a medical practitioner and can behave incorrectly if the proper pressure is not applied. This paper takes advantage of recent research and develops a simulator based on a deep sequence model to predict airway pressure in the respiratory circuit during the inspiratory phase of a breath given a time series of control parameters and lung attributes. This method demonstrates the effectiveness of neural network-based controllers in tracking pressure wave forms significantly better than the current industry standard and provides insights into the development of effective and robust pressure-controlled mechanical ventilators. The paper will measure as the mean absolute error between the predicted and actual pressures during the inspiratory phase of each breath.

Zenodo (CERN European Organization for Nuclear Research)
University of California, Los Angeles (US), Digital Science (United States) (US), Case Western Reserve University (US), Auburn University (US)
Openalex Percentile: Top 50%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.