QUANTITATIVE ESTIMATION OF HYOSCINE BUTYL BROMIDE AND PARACETAMOL IN TABLET DOSAGE FORMS BY RP-HPLC METHOD

A new, simple, rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validation of Hyoscine butyl bromide and Paracetamol in its pure form as well as in combined marketed formulation. Chromatography was carried out on a X bridge C18 (4.6mm×150mm) 5µm particle size column using a mixture of ACN: Methanol (70:30% v/v) as the mobile phase at a flow rate of 1.2ml/min, the detection was carried out at 260nm. The method was validated according to ICH guidelines for linearity, sensitivity, accuracy, precision, specificity and robustness. The method produce linear responses in the concentration range of 20-60mg/ml of Hyoscine butyl bromide and 10-30mg/ml of Paracetamol. The inter-day and intra-day precisions were found to be within limits. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations. Keywords: Hyoscine butyl bromide and Paracetamol, RP-HPLC, Validation, Accuracy, Precision.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-10-07
DOI
https://doi.org/10.5281/zenodo.13899820
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QUANTITATIVE ESTIMATION OF HYOSCINE BUTYL BROMIDE AND PARACETAMOL IN TABLET DOSAGE FORMS BY RP-HPLC METHOD

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

QUANTITATIVE ESTIMATION OF HYOSCINE BUTYL BROMIDE AND PARACETAMOL IN TABLET DOSAGE FORMS BY RP-HPLC METHOD

article en

Abstract

A new, simple, rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validation of Hyoscine butyl bromide and Paracetamol in its pure form as well as in combined marketed formulation. Chromatography was carried out on a X bridge C18 (4.6mm×150mm) 5µm particle size column using a mixture of ACN: Methanol (70:30% v/v) as the mobile phase at a flow rate of 1.2ml/min, the detection was carried out at 260nm. The method was validated according to ICH guidelines for linearity, sensitivity, accuracy, precision, specificity and robustness. The method produce linear responses in the concentration range of 20-60mg/ml of Hyoscine butyl bromide and 10-30mg/ml of Paracetamol. The inter-day and intra-day precisions were found to be within limits. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations. Keywords: Hyoscine butyl bromide and Paracetamol, RP-HPLC, Validation, Accuracy, Precision.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 68%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.