Assessing Façade-Mounted Windcatcher Supply Outlet Height's Influence on Indoor Air Quality in Residential Bedrooms

The optimum location of a windcatcher supply outlet on the facade of a building in relation to the occupant breathing zone in the context of indoor air quality (IAQ) is imperative. This study attempts to determine the optimum location of the windcatcher supply outlet on the facade of a bedroom for enhanced IAQ. The building model was created using Design Builder software while computational fluid dynamics (CFD) was employed for the parametric simulation using air change effectiveness (ACE) as the optimization objective function. The height of the windcatcher supply outlet was varied from 0.2m to 2.4m step 0.2m above the floor level. The results show that higher values of ACE in the occupants’ breathing zone were obtained at lower heights of the windcatcher supply outlets with the best ACE of 1.13 obtained at 0.4m. This information could help engineers to optimally position the windcatcher supply outlet on the façade of a bedroom building or any other building with similar attributes.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-08-31
DOI
https://doi.org/10.5281/zenodo.13843236
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Façade-Mounted Windcatcher Supply Outlet Height's Influence on Indoor Air Quality in Residential Bedrooms

Zenodo (CERN European Organization for Nuclear Research)
Wind and Air Flow Studies
article

Assessing Façade-Mounted Windcatcher Supply Outlet Height's Influence on Indoor Air Quality in Residential Bedrooms

article en

Abstract

The optimum location of a windcatcher supply outlet on the facade of a building in relation to the occupant breathing zone in the context of indoor air quality (IAQ) is imperative. This study attempts to determine the optimum location of the windcatcher supply outlet on the facade of a bedroom for enhanced IAQ. The building model was created using Design Builder software while computational fluid dynamics (CFD) was employed for the parametric simulation using air change effectiveness (ACE) as the optimization objective function. The height of the windcatcher supply outlet was varied from 0.2m to 2.4m step 0.2m above the floor level. The results show that higher values of ACE in the occupants’ breathing zone were obtained at lower heights of the windcatcher supply outlets with the best ACE of 1.13 obtained at 0.4m. This information could help engineers to optimally position the windcatcher supply outlet on the façade of a bedroom building or any other building with similar attributes.

Zenodo (CERN European Organization for Nuclear Research)
The Federal Polytechnic, Ado-Ekiti (NG), Federal Polytechnic, Mubi
Sustainable cities and communities
Openalex Percentile: Top 70%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.