Accuracy of Mammography and Ultrasound in Detecting Breast Cancer A Prospective Comparative Study

Background: Breast cancer remains a significant public health concern, and the earlydetection of the disease is crucial for improving patient outcomes. This prospective,comparative study aimed to meticulously evaluate and compare the accuracy ofmammography and ultrasound in detecting breast cancer, focusing on their sensitivity,specificity, positive predictive value (PPV), and negative predictive value(NPV).Methods: A total of 250 women aged 40 to 75 years, presenting for routinescreening or with symptomatic breast complaints, were included in the study.Participants underwent digital mammography and high-resolution ultrasoundexaminations, with the findings classified according to the Breast Imaging Reportingand Data System (BI-RADS). Biopsy-confirmed results served as the referencestandard.Results: Of the 250 participants, 36 (14.4%) were found to have biopsyconfirmed breast cancer. Ultrasound demonstrated a higher sensitivity of 94.4% (95%CI: 80.8%-99.3%) compared to mammography at 83.3% (95% CI: 67.2%-93.6%), witha statistically significant difference in detection rates (p = 0.031). The combined use ofboth modalities achieved the highest sensitivity of 97.2% (95% CI: 85.5%-99.9%). Thespecificity was 89.4% for mammography and 87.0% for ultrasound, with a modestdecrease to 86.4% for the combined approach. The PPV ranged from 57.4% to 60.0%,while the NPV was exceptionally high, reaching 99.5% for the combinedmodalities.Conclusion: Ultrasound demonstrated superior sensitivity compared tomammography in detecting breast cancer, particularly in women with dense breasts.The combined use of both modalities resulted in the highest sensitivity, suggesting thata multimodal approach may be the most effective strategy for comprehensive breastcancer screening and diagnosis.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-10-21
DOI
https://doi.org/10.5281/zenodo.13960255
Primary Topic
Breast Lesions and Carcinomas
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Mammography and Ultrasound in Detecting Breast Cancer A Prospective Comparative Study

Zenodo (CERN European Organization for Nuclear Research)
Breast Lesions and Carcinomas
article

Accuracy of Mammography and Ultrasound in Detecting Breast Cancer A Prospective Comparative Study

article en

Abstract

Background: Breast cancer remains a significant public health concern, and the earlydetection of the disease is crucial for improving patient outcomes. This prospective,comparative study aimed to meticulously evaluate and compare the accuracy ofmammography and ultrasound in detecting breast cancer, focusing on their sensitivity,specificity, positive predictive value (PPV), and negative predictive value(NPV).Methods: A total of 250 women aged 40 to 75 years, presenting for routinescreening or with symptomatic breast complaints, were included in the study.Participants underwent digital mammography and high-resolution ultrasoundexaminations, with the findings classified according to the Breast Imaging Reportingand Data System (BI-RADS). Biopsy-confirmed results served as the referencestandard.Results: Of the 250 participants, 36 (14.4%) were found to have biopsyconfirmed breast cancer. Ultrasound demonstrated a higher sensitivity of 94.4% (95%CI: 80.8%-99.3%) compared to mammography at 83.3% (95% CI: 67.2%-93.6%), witha statistically significant difference in detection rates (p = 0.031). The combined use ofboth modalities achieved the highest sensitivity of 97.2% (95% CI: 85.5%-99.9%). Thespecificity was 89.4% for mammography and 87.0% for ultrasound, with a modestdecrease to 86.4% for the combined approach. The PPV ranged from 57.4% to 60.0%,while the NPV was exceptionally high, reaching 99.5% for the combinedmodalities.Conclusion: Ultrasound demonstrated superior sensitivity compared tomammography in detecting breast cancer, particularly in women with dense breasts.The combined use of both modalities resulted in the highest sensitivity, suggesting thata multimodal approach may be the most effective strategy for comprehensive breastcancer screening and diagnosis.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 54%
Breast Lesions and Carcinomas
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of Mammography and Ultrasound in Detecting Breast Cancer A Prospective Comparative Study · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS