Predicting the impact of target volume contouring variations on the organ at risk dose: results of a qualitative survey

Purpose Integrating auto-contouring in radiotherapy workflows is shifting the role of radiation oncologists from manual delineation to reviewing and correcting automatically generated contours. However, we postulate that this process is hindered by significant inter-evaluator variability in assessing the dosimetric impact of contour variations. This study investigates how radiation oncologists and medical physicists evaluate the impact of glioblastoma target volume (TV) variations on the dose to organs at risk (OARs), focusing on understanding inter-evaluator variability and decision-making patterns. Methods A qualitative survey was conducted involving four radiation oncologists and three medical physicists. Participants classified 54 glioblastoma TV contour variations using up to four changes each across 14 patients as “better,” “no change,” or “worse” regarding their expected impact on the dose to OARs. The corresponding ground truth labels were derived from standardized treatment plans. Inter-evaluator variability was analyzed using Cohen’s Kappa. Results Substantial variability was observed, with Cohen’s Kappa values ranging from weak to moderate agreement (0.33–0.74). Evaluators frequently overestimated the negative impact of contour variations, misclassifying 46% of “no change” variations as “Worse.” No evaluator judged contour variations as resulting in “better” doses to OARs, despite this being the case for 4 variations. Conclusion Significant variability in estimating the dosimetric impact of contour variations underscores the critical need for standardized guidelines to reduce inconsistencies and allow for the assessment of automatically generated contours based on clinically meaningful factors. Evaluators frequently overestimated the negative impact of contour variations, potentially leading to inefficiencies and unnecessary contour corrections in clinical practice.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-06-30
DOI
https://doi.org/10.48620/88945
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predicting the impact of target volume contouring variations on the organ at risk dose: results of a qualitative survey

Open Access CRIS of the University of Bern
Advanced Radiotherapy Techniques
article

Predicting the impact of target volume contouring variations on the organ at risk dose: results of a qualitative survey

article en

Abstract

Purpose Integrating auto-contouring in radiotherapy workflows is shifting the role of radiation oncologists from manual delineation to reviewing and correcting automatically generated contours. However, we postulate that this process is hindered by significant inter-evaluator variability in assessing the dosimetric impact of contour variations. This study investigates how radiation oncologists and medical physicists evaluate the impact of glioblastoma target volume (TV) variations on the dose to organs at risk (OARs), focusing on understanding inter-evaluator variability and decision-making patterns. Methods A qualitative survey was conducted involving four radiation oncologists and three medical physicists. Participants classified 54 glioblastoma TV contour variations using up to four changes each across 14 patients as “better,” “no change,” or “worse” regarding their expected impact on the dose to OARs. The corresponding ground truth labels were derived from standardized treatment plans. Inter-evaluator variability was analyzed using Cohen’s Kappa. Results Substantial variability was observed, with Cohen’s Kappa values ranging from weak to moderate agreement (0.33–0.74). Evaluators frequently overestimated the negative impact of contour variations, misclassifying 46% of “no change” variations as “Worse.” No evaluator judged contour variations as resulting in “better” doses to OARs, despite this being the case for 4 variations. Conclusion Significant variability in estimating the dosimetric impact of contour variations underscores the critical need for standardized guidelines to reduce inconsistencies and allow for the assessment of automatically generated contours based on clinically meaningful factors. Evaluators frequently overestimated the negative impact of contour variations, potentially leading to inefficiencies and unnecessary contour corrections in clinical practice.

Open Access CRIS of the University of Bern
Artificial Intelligence in Medicine (Canada) (CA), HP Family Medical Clinic (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 45%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Predicting the impact of target volume contouring variations on the organ at risk dose: results of a qualitative survey · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS