Validation of a dynamic 4D microsurgical bypass simulator for training and teaching microvascular anastomosis techniques with blood flow and fluorescence imaging.

Objective Microvascular anastomosis is challenging, and training surgeons to develop and maintain skills is imperative. Current training models either miss the simulation of the surgical workflow, lack 3D key-hole space, need ethical approval, require special preparation, or lack realism. To circumvent these issues, this study describes the use of a mixed reality 3D printed model with integrated blood flow for training cerebral anastomosis and assesses its validity. Methods Different-sized 3D-printed artificial micro artery models in a 3D brain space with a keyhole opening were used. The model was connected to a 4D simulator to induce pulsatile blood flow. Neurosurgical microscopes and exoscopes were used for visualization. Nine participants (n = 6 board-certified cerebrovascular neurosurgeons; n = 3 in-training) participated in the study and practiced anastomosis techniques with the simulator. Two senior, experienced vascular neurosurgeons mentored live teaching activity on the simulator. Participants completed a survey to score the face and content validity of the simulation on a 5-point Likert scale. Simulation time and anastomosis score differences between in-training and board-certified participants were compared for construct validity. Results Participants scored the simulation difficulty similar to actual surgery, proving face validity. All participants agreed that practice on the provided simulator models would improve bypass techniques (μ = 4.67/5 ± 0.47) and instrument handling (μ = 4.56/5 ± 0.68). Board-certified participants had better anastomosis scores than in-training participants (non-significant difference). Conclusions The 4D simulator and the high-fidelity artificial 3D printed model effectively simulated actual bypass surgery in a key-hole fashion with blood flow abilities. Limited resources and preparation time are needed for the training setup. The model provides benefits in learning and maintaining anastomosis skills and allows for easy adaptation to different microanatomical scenarios.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-10-01
DOI
https://doi.org/10.48620/76265
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a dynamic 4D microsurgical bypass simulator for training and teaching microvascular anastomosis techniques with blood flow and fluorescence imaging.

Open Access CRIS of the University of Bern
Surgical Simulation and Training
article

Validation of a dynamic 4D microsurgical bypass simulator for training and teaching microvascular anastomosis techniques with blood flow and fluorescence imaging.

article en

Abstract

Objective Microvascular anastomosis is challenging, and training surgeons to develop and maintain skills is imperative. Current training models either miss the simulation of the surgical workflow, lack 3D key-hole space, need ethical approval, require special preparation, or lack realism. To circumvent these issues, this study describes the use of a mixed reality 3D printed model with integrated blood flow for training cerebral anastomosis and assesses its validity. Methods Different-sized 3D-printed artificial micro artery models in a 3D brain space with a keyhole opening were used. The model was connected to a 4D simulator to induce pulsatile blood flow. Neurosurgical microscopes and exoscopes were used for visualization. Nine participants (n = 6 board-certified cerebrovascular neurosurgeons; n = 3 in-training) participated in the study and practiced anastomosis techniques with the simulator. Two senior, experienced vascular neurosurgeons mentored live teaching activity on the simulator. Participants completed a survey to score the face and content validity of the simulation on a 5-point Likert scale. Simulation time and anastomosis score differences between in-training and board-certified participants were compared for construct validity. Results Participants scored the simulation difficulty similar to actual surgery, proving face validity. All participants agreed that practice on the provided simulator models would improve bypass techniques (μ = 4.67/5 ± 0.47) and instrument handling (μ = 4.56/5 ± 0.68). Board-certified participants had better anastomosis scores than in-training participants (non-significant difference). Conclusions The 4D simulator and the high-fidelity artificial 3D printed model effectively simulated actual bypass surgery in a key-hole fashion with blood flow abilities. Limited resources and preparation time are needed for the training setup. The model provides benefits in learning and maintaining anastomosis skills and allows for easy adaptation to different microanatomical scenarios.

Open Access CRIS of the University of Bern
Guided Therapeutics (United States) (US)
Quality Education
Openalex Percentile: Top 49%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of a dynamic 4D microsurgical bypass simulator for training and teaching microvascular anastomosis techniques with blood flow and fluorescence imaging. · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS