Limitations of SpO2 / FiO2-ratio for classification and monitoring of acute respiratory distress syndrome—an observational cohort study

Background The ratio of pulse-oximetric peripheral oxygen saturation to fraction of inspired oxygen (SpO$_{2}$/FiO$_{2}$) has been proposed as additional hypoxemia criterion in a new global definition of acute respiratory distress syndrome (ARDS). This study aims to evaluate the clinical and theoretical limitations of the SpO$_{2}$/FiO$_{2}$-ratio when using it to classify patients with ARDS and to follow disease progression. Methods Observational cohort study of ARDS patients from three high-resolution Intensive Care Unit databases, including our own database ICU Cockpit, MIMIC-IV (Version 3.0) and SICdb (Version 1.0.6). Patients with ARDS were identified based on the Berlin criteria or ICD 9/10-codes. Time-matched datapoints of SpO$_{2}$, FiO$_{2}$ and partial pressure of oxygen in arterial blood (PaO$_{2}$) were created. Severity classification followed the thresholds for SpO$_{2}$/FiO$_{2}$ and PaO$_{2}$/FiO$_{2}$ of the newly proposed global definition. Results Overall, 708 ARDS patients were included in the analysis. ARDS severity was misclassified by SpO$_{2}$/FiO$_{2}$ in 33% of datapoints, out of which 84% were classified as more severe. This can be partially explained by imprecision of SpO$_{2}$ measurement and equation used to transform SpO$_{2}$/FiO$_{2}$ to PaO$_{2}$/FiO$_{2.}$ A high dependence of SpO$_{2}$/FiO$_{2}$-ratio on FiO$_{2}$ settings was found, leading to major treatment effect and limited capability for tracking change in ARDS severity, which was achieved in less than 20% of events. Conclusions The use of SpO$_{2}$/FiO$_{2}$ interchangeably with PaO$_{2}$/FiO$_{2}$ for severity classification and monitoring of ARDS is limited by its inadequate trending ability and high dependence on FiO$_{2}$ settings, which may influence treatment decisions and patient selection in clinical trials.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2025-02-19
DOI
https://doi.org/10.5167/uzh-275898
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Limitations of SpO2 / FiO2-ratio for classification and monitoring of acute respiratory distress syndrome—an observational cohort study

Zurich Open Repository and Archive (University of Zurich)
Respiratory Support and Mechanisms
article

Limitations of SpO2 / FiO2-ratio for classification and monitoring of acute respiratory distress syndrome—an observational cohort study

article en

Abstract

Background The ratio of pulse-oximetric peripheral oxygen saturation to fraction of inspired oxygen (SpO$_{2}$/FiO$_{2}$) has been proposed as additional hypoxemia criterion in a new global definition of acute respiratory distress syndrome (ARDS). This study aims to evaluate the clinical and theoretical limitations of the SpO$_{2}$/FiO$_{2}$-ratio when using it to classify patients with ARDS and to follow disease progression. Methods Observational cohort study of ARDS patients from three high-resolution Intensive Care Unit databases, including our own database ICU Cockpit, MIMIC-IV (Version 3.0) and SICdb (Version 1.0.6). Patients with ARDS were identified based on the Berlin criteria or ICD 9/10-codes. Time-matched datapoints of SpO$_{2}$, FiO$_{2}$ and partial pressure of oxygen in arterial blood (PaO$_{2}$) were created. Severity classification followed the thresholds for SpO$_{2}$/FiO$_{2}$ and PaO$_{2}$/FiO$_{2}$ of the newly proposed global definition. Results Overall, 708 ARDS patients were included in the analysis. ARDS severity was misclassified by SpO$_{2}$/FiO$_{2}$ in 33% of datapoints, out of which 84% were classified as more severe. This can be partially explained by imprecision of SpO$_{2}$ measurement and equation used to transform SpO$_{2}$/FiO$_{2}$ to PaO$_{2}$/FiO$_{2.}$ A high dependence of SpO$_{2}$/FiO$_{2}$-ratio on FiO$_{2}$ settings was found, leading to major treatment effect and limited capability for tracking change in ARDS severity, which was achieved in less than 20% of events. Conclusions The use of SpO$_{2}$/FiO$_{2}$ interchangeably with PaO$_{2}$/FiO$_{2}$ for severity classification and monitoring of ARDS is limited by its inadequate trending ability and high dependence on FiO$_{2}$ settings, which may influence treatment decisions and patient selection in clinical trials.

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 39%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.