MyVet and MyDoc - a laboratory in your phone

Background: Quantifying erythrocytes and leukocytes is crucial in veterinary diagnostics. Traditional methods like flow cytometry, laser scattering, and impedance detection, while accurate, require significant sample volumes and complex preparation. Emerging point-of-care (POC) technologies have identified visible-near infrared (Vis-NIR) spectroscopy as a promising, minimally invasive alternative. Objective: This study aims to establish direct correlations between blood cell counts (erythrocytes, leukocytes, hemoglobin, and hematocrit) and scattering coefficients from whole blood spectra, supporting the development of portable, reagent-free diagnostic tools for veterinary use. Methods: Fresh canine blood was collected via standard venipuncture at Anicura CHV - Veterinary Hospital Center. Spectral data were captured using a 4500K LED and Ocean Insight STS-vis spectrometer (300-800 nm). Scattering correction coefficients were calculated using an extended multiplicative scattering correction algorithm, and multivariate linear regression (MLR) models were used to assess the relationship between scattering data and hemogram parameters. Model performance was evaluated using Pearson correlation (R), mean absolute error percentage (MAPE), and coefficient of determination (R²). Results: Fig. 1 presents the correlation plots for RBC, Hgb, HTC, and WBC, while Fig. 2 shows the scattering quantification. A moderate correlation between scattering coefficients and RBC counts (R=0.5739) was observed, with a standard error (SE) of 1.30×10¹² and MAPE of 21.48%, suggesting that scattering data can reflect RBC levels despite notable variance. Hgb, which is closely linked to RBC, showed a similar correlation (R=0.5623), with a MAPE of 22.66% and SE of 32.51 g/dL, indicating potential for qualitative Hgb assessment. WBC correlations were weaker (R=0.4270) but demonstrated potential within the official recommended range. Conclusions: These findings confirm that scattering coefficients contain valuable information about blood cell counts, supporting the viability of Vis-NIR spectroscopy for non-invasive hemogram diagnostics. However, variability in the data highlights the need for self-learning artificial intelligence (SLAI) correction models to enhance accuracy, particularly for less abundant components like WBC. This approach holds promise for transforming POC testing into clinical and field settings.

Publication Details

Journal
Science Letters
Published
2025-05-07
DOI
https://doi.org/10.48797/sl.2025.372
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MyVet and MyDoc - a laboratory in your phone

Science Letters
Biosensors and Analytical Detection
article

MyVet and MyDoc - a laboratory in your phone

article en

Abstract

Background: Quantifying erythrocytes and leukocytes is crucial in veterinary diagnostics. Traditional methods like flow cytometry, laser scattering, and impedance detection, while accurate, require significant sample volumes and complex preparation. Emerging point-of-care (POC) technologies have identified visible-near infrared (Vis-NIR) spectroscopy as a promising, minimally invasive alternative. Objective: This study aims to establish direct correlations between blood cell counts (erythrocytes, leukocytes, hemoglobin, and hematocrit) and scattering coefficients from whole blood spectra, supporting the development of portable, reagent-free diagnostic tools for veterinary use. Methods: Fresh canine blood was collected via standard venipuncture at Anicura CHV - Veterinary Hospital Center. Spectral data were captured using a 4500K LED and Ocean Insight STS-vis spectrometer (300-800 nm). Scattering correction coefficients were calculated using an extended multiplicative scattering correction algorithm, and multivariate linear regression (MLR) models were used to assess the relationship between scattering data and hemogram parameters. Model performance was evaluated using Pearson correlation (R), mean absolute error percentage (MAPE), and coefficient of determination (R²). Results: Fig. 1 presents the correlation plots for RBC, Hgb, HTC, and WBC, while Fig. 2 shows the scattering quantification. A moderate correlation between scattering coefficients and RBC counts (R=0.5739) was observed, with a standard error (SE) of 1.30×10¹² and MAPE of 21.48%, suggesting that scattering data can reflect RBC levels despite notable variance. Hgb, which is closely linked to RBC, showed a similar correlation (R=0.5623), with a MAPE of 22.66% and SE of 32.51 g/dL, indicating potential for qualitative Hgb assessment. WBC correlations were weaker (R=0.4270) but demonstrated potential within the official recommended range. Conclusions: These findings confirm that scattering coefficients contain valuable information about blood cell counts, supporting the viability of Vis-NIR spectroscopy for non-invasive hemogram diagnostics. However, variability in the data highlights the need for self-learning artificial intelligence (SLAI) correction models to enhance accuracy, particularly for less abundant components like WBC. This approach holds promise for transforming POC testing into clinical and field settings.

Science Letters
Life below water
Openalex Percentile: Top 57%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MyVet and MyDoc - a laboratory in your phone · Science Letters (2025) | TGRS Research Map | TGRS