Implant-supported fixed complete denture frameworks in additively and subtractively manufactured high-performance polymers: Fabrication and fit accuracy.

Objective To compare the fabrication and fit accuracy of additively (AM) and subtractively (SM) manufactured implant-supported fixed complete denture (ISFCD) frameworks in high-performance polymers with those in titanium.Methods An edentulous maxillary model with four implants (right first molar, right canine, left canine, and left right first molar) was digitized to design an ISFCD framework, which was used to fabricate a total of 50 frameworks in polyetheretherketone (AM-PEEK and SM-PEEK), polyetherketoneketone (AM-PEKK and SM-PEKK), and titanium (SM-Ti) (n = 10). A laboratory scanner was used to digitize each framework and when the frameworks were seated on the model at the left first molar site with the 1-screw test. The scan files of the frameworks were superimposed over the design file to evaluate the surface and interimplant deviations, while the fit at right first molar, right canine, and left canine sites was assessed with the average gap values. Data were statistically analyzed (α = 0.05).Results SM-PEEK and SM-Ti frameworks mostly had higher and AM frameworks mostly had lower surface accuracy (P ≤ 0.036). SM-Ti and SM-PEEK frameworks had the lowest molar-to-molar interimplant distance deviations, and AM frameworks had the lowest precision of interimplant distances (P ≤ 0.014) AM-PEKK frameworks mostly had lower average gap accuracy regardless of the abutment site, followed by AM-PEEK (P < 0.001).Conclusions SM-PEEK and SM-Ti frameworks mostly had higher and AM frameworks mostly had lower accuracy. AM frameworks had larger marginal gaps. Tested frameworks tended to distort towards the midline.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-05-21
DOI
https://doi.org/10.48620/89259
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implant-supported fixed complete denture frameworks in additively and subtractively manufactured high-performance polymers: Fabrication and fit accuracy.

Open Access CRIS of the University of Bern
Dental Implant Techniques and Outcomes
article

Implant-supported fixed complete denture frameworks in additively and subtractively manufactured high-performance polymers: Fabrication and fit accuracy.

article en

Abstract

Objective To compare the fabrication and fit accuracy of additively (AM) and subtractively (SM) manufactured implant-supported fixed complete denture (ISFCD) frameworks in high-performance polymers with those in titanium.Methods An edentulous maxillary model with four implants (right first molar, right canine, left canine, and left right first molar) was digitized to design an ISFCD framework, which was used to fabricate a total of 50 frameworks in polyetheretherketone (AM-PEEK and SM-PEEK), polyetherketoneketone (AM-PEKK and SM-PEKK), and titanium (SM-Ti) (n = 10). A laboratory scanner was used to digitize each framework and when the frameworks were seated on the model at the left first molar site with the 1-screw test. The scan files of the frameworks were superimposed over the design file to evaluate the surface and interimplant deviations, while the fit at right first molar, right canine, and left canine sites was assessed with the average gap values. Data were statistically analyzed (α = 0.05).Results SM-PEEK and SM-Ti frameworks mostly had higher and AM frameworks mostly had lower surface accuracy (P ≤ 0.036). SM-Ti and SM-PEEK frameworks had the lowest molar-to-molar interimplant distance deviations, and AM frameworks had the lowest precision of interimplant distances (P ≤ 0.014) AM-PEKK frameworks mostly had lower average gap accuracy regardless of the abutment site, followed by AM-PEEK (P < 0.001).Conclusions SM-PEEK and SM-Ti frameworks mostly had higher and AM frameworks mostly had lower accuracy. AM frameworks had larger marginal gaps. Tested frameworks tended to distort towards the midline.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 42%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Implant-supported fixed complete denture frameworks in additively and subtractively manufactured high-performance polymers: Fabrication and fit accuracy. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS