Interexaminer agreement of gonioscopy examinations in dogs using the European College of Veterinary Ophthalmologists Hereditary Eye Diseases grading scheme

ObjectiveProspective observational study with preregistered study protocol to assess interexaminer agreement using the 2022 European College of Veterinary Ophthalmologists Hereditary Eye Disease (ECVO‐HED) gonioscopy grading scheme.Animals StudiedSixty client‐owned dogs presented for gonioscopy as part of the required certification process prior to breeding.ProcedureTwo ECVO diplomates with comparable clinical experience performed gonioscopy with a Koeppe gonioscopy lens and slit‐lamp biomicroscope at 10x magnification on all eyes in a randomized fashion.ResultsOne hundred and eighteen of 120 eyes (60 dogs) were included. In 110/118 eyes (93%), both examiners provided the same breeding recommendation (yes/no). This translated into an agreement on the final breeding recommendation in 58/60 dogs (97%). Examiners disagreed on pectinate ligament abnormality (PLA) grading in 19/118 eyes and iridocorneal angle width (ICAW) grading in 9/118 eyes. PLA grading disagreement was mostly observed between neighboring grades. Disagreement between PLA and ICAW grading sometimes occurred within the same eye accounting for an observed disagreement in iridocorneal angle abnormality (ICAA) grading in 19/118 eyes in total. Cohen's kappa was Κ = 0.62 (95% TI 0.34–0.89), whereas maximum kappa was maxΚ = 0.82 (95% TI 0.59–1). Mixed model analysis suggested no significant examiner influence on breeding recommendations (OR 0.17; 95% CI 0.02–1.12, p = .09).ConclusionsAlthough examiners disagreed on ICAA grading in 19/118 eyes, this resulted in a different breeding recommendation (yes/no) in eight eyes and in two dogs only. Therefore, the use of the 2022 ECVO‐HED gonioscopy grading scheme seems to result in examiners providing the same breeding recommendations in most cases.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-10-31
DOI
https://doi.org/10.5167/uzh-271401
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interexaminer agreement of gonioscopy examinations in dogs using the European College of Veterinary Ophthalmologists Hereditary Eye Diseases grading scheme

Zurich Open Repository and Archive (University of Zurich)
Ocular Surface and Contact Lens
article

Interexaminer agreement of gonioscopy examinations in dogs using the European College of Veterinary Ophthalmologists Hereditary Eye Diseases grading scheme

article en

Abstract

ObjectiveProspective observational study with preregistered study protocol to assess interexaminer agreement using the 2022 European College of Veterinary Ophthalmologists Hereditary Eye Disease (ECVO‐HED) gonioscopy grading scheme.Animals StudiedSixty client‐owned dogs presented for gonioscopy as part of the required certification process prior to breeding.ProcedureTwo ECVO diplomates with comparable clinical experience performed gonioscopy with a Koeppe gonioscopy lens and slit‐lamp biomicroscope at 10x magnification on all eyes in a randomized fashion.ResultsOne hundred and eighteen of 120 eyes (60 dogs) were included. In 110/118 eyes (93%), both examiners provided the same breeding recommendation (yes/no). This translated into an agreement on the final breeding recommendation in 58/60 dogs (97%). Examiners disagreed on pectinate ligament abnormality (PLA) grading in 19/118 eyes and iridocorneal angle width (ICAW) grading in 9/118 eyes. PLA grading disagreement was mostly observed between neighboring grades. Disagreement between PLA and ICAW grading sometimes occurred within the same eye accounting for an observed disagreement in iridocorneal angle abnormality (ICAA) grading in 19/118 eyes in total. Cohen's kappa was Κ = 0.62 (95% TI 0.34–0.89), whereas maximum kappa was maxΚ = 0.82 (95% TI 0.59–1). Mixed model analysis suggested no significant examiner influence on breeding recommendations (OR 0.17; 95% CI 0.02–1.12, p = .09).ConclusionsAlthough examiners disagreed on ICAA grading in 19/118 eyes, this resulted in a different breeding recommendation (yes/no) in eight eyes and in two dogs only. Therefore, the use of the 2022 ECVO‐HED gonioscopy grading scheme seems to result in examiners providing the same breeding recommendations in most cases.

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 53%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interexaminer agreement of gonioscopy examinations in dogs using the European College of Veterinary Ophthalmologists Hereditary Eye Diseases grading scheme · Zurich Open Repository and Archive (University of Zurich) (2024) | TGRS Research Map | TGRS