Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences.

Pulmonary complications are known to occur in patients after Fontan palliation. Cardiac MRI is performed in the follow-up of Fontan patients to assess single ventricular function, hemodynamics and potential collateral flow. To date, pulmonary function tests have been used to detect functional lung impairment, but lung MRI has not been integrated into imaging follow-up. In this study, we measured lung-to-background ratio (LBR) on zero echo time (ZTE) MRI sequences in 32 children with Fontan palliation. Patients were divided into 2 groups: LBR > 1.5 and < 1.5 and assessed for associations between LBR and ventricular function, fibrosis, hemodynamics as well as biomarkers, spirometry and previous catheter results. We observed significantly increased extracellular volume (ECV) and decreased tissue inhibitor of metalloproteinase 1 (TIMP-1), soluble suppression of tumorigenicity 2 (sST-2) and a trend towards decreased growth differentiation factor 15 (GDF-15) as well as decreased albumin and prothrombin time values in patients with elevated LBR, whereas the other cardiovascular and pulmonary parameters did not differ significantly. Moreover, patients with LBR > 1.5 had a history of increased pulmonary arterial pressure prior to the Fontan and Glenn procedures and interventional veno-venous collateral embolization. Monitoring lung density with ZTE MRI sequences may be helpful in the diagnostic workup to assess the outcome of patients after Fontan procedure.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-11
DOI
https://doi.org/10.48620/87272
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences.

Open Access CRIS of the University of Bern
Congenital Heart Disease Studies
article

Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences.

article en

Abstract

Pulmonary complications are known to occur in patients after Fontan palliation. Cardiac MRI is performed in the follow-up of Fontan patients to assess single ventricular function, hemodynamics and potential collateral flow. To date, pulmonary function tests have been used to detect functional lung impairment, but lung MRI has not been integrated into imaging follow-up. In this study, we measured lung-to-background ratio (LBR) on zero echo time (ZTE) MRI sequences in 32 children with Fontan palliation. Patients were divided into 2 groups: LBR > 1.5 and < 1.5 and assessed for associations between LBR and ventricular function, fibrosis, hemodynamics as well as biomarkers, spirometry and previous catheter results. We observed significantly increased extracellular volume (ECV) and decreased tissue inhibitor of metalloproteinase 1 (TIMP-1), soluble suppression of tumorigenicity 2 (sST-2) and a trend towards decreased growth differentiation factor 15 (GDF-15) as well as decreased albumin and prothrombin time values in patients with elevated LBR, whereas the other cardiovascular and pulmonary parameters did not differ significantly. Moreover, patients with LBR > 1.5 had a history of increased pulmonary arterial pressure prior to the Fontan and Glenn procedures and interventional veno-venous collateral embolization. Monitoring lung density with ZTE MRI sequences may be helpful in the diagnostic workup to assess the outcome of patients after Fontan procedure.

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 45%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS