Can an increase in abutment screw length enable biomechanical advantages for implants with increased crown height space?

Purpose The purpose of this finite element analysis (FEA) study was to investigate how screw length and crown height affect the stresses generated in the implant-abutment complex and alveolar bone for anterior single implants and whether the use of longer abutment screw would compensate for increased stresses originated from increased crown height space (CHS). Materials And Methods A maxillary anterior segment was modeled, and one implant (Straumann bone level implants, 4.1 mm × 12 mm) was placed at the central incisor site. Three different crown heights (11, 13, and 15 mm) with two different abutment screw lengths (regular [R] 7.9 and long [L] 9.9 mm) were modeled, and coded as M 11-R, M 13-R, M 15-R, M 11-L, M 13-L, and M 15-L depending on the height and length, respectively. Horizontal (25.5 N) and 30-degree oblique forces (178 N) were applied to the crown. The stress magnitude and distribution were evaluated. Results M 15-L showed the highest von Mises stress value (869.72 MPa) at the abutment under oblique loads. For both screw lengths, von Mises stress values in the abutment, abutment screw, and inside and outside of the implant walls around the implant platform increased with increased crown height. With the increase in length of the abutment screw, the von Mises stresses decreased in the inside and outside walls of the implant, while the stresses in the abutment increased. Conclusions Abutment screw length and crown height affected the amount of stress generated on implant components. Increasing the screw length may reduce the stresses on the implant and bone without increasing the stresses in the screw, potentially mitigating the risk of implant platform fractures and bone resorption, both of which are critical failures. Screw related issues may decrease as the area stresses effect has a tendency to reduce when longer screw is used in increased CHS situation (tall crowns).

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-05-15
DOI
https://doi.org/10.48620/89114
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can an increase in abutment screw length enable biomechanical advantages for implants with increased crown height space?

Open Access CRIS of the University of Bern
Dental Implant Techniques and Outcomes
article

Can an increase in abutment screw length enable biomechanical advantages for implants with increased crown height space?

article en

Abstract

Purpose The purpose of this finite element analysis (FEA) study was to investigate how screw length and crown height affect the stresses generated in the implant-abutment complex and alveolar bone for anterior single implants and whether the use of longer abutment screw would compensate for increased stresses originated from increased crown height space (CHS). Materials And Methods A maxillary anterior segment was modeled, and one implant (Straumann bone level implants, 4.1 mm × 12 mm) was placed at the central incisor site. Three different crown heights (11, 13, and 15 mm) with two different abutment screw lengths (regular [R] 7.9 and long [L] 9.9 mm) were modeled, and coded as M 11-R, M 13-R, M 15-R, M 11-L, M 13-L, and M 15-L depending on the height and length, respectively. Horizontal (25.5 N) and 30-degree oblique forces (178 N) were applied to the crown. The stress magnitude and distribution were evaluated. Results M 15-L showed the highest von Mises stress value (869.72 MPa) at the abutment under oblique loads. For both screw lengths, von Mises stress values in the abutment, abutment screw, and inside and outside of the implant walls around the implant platform increased with increased crown height. With the increase in length of the abutment screw, the von Mises stresses decreased in the inside and outside walls of the implant, while the stresses in the abutment increased. Conclusions Abutment screw length and crown height affected the amount of stress generated on implant components. Increasing the screw length may reduce the stresses on the implant and bone without increasing the stresses in the screw, potentially mitigating the risk of implant platform fractures and bone resorption, both of which are critical failures. Screw related issues may decrease as the area stresses effect has a tendency to reduce when longer screw is used in increased CHS situation (tall crowns).

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 42%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.