Phakic implantable collamer lens implantation for correcting low-to-moderate myopia

AIM:To investigate the clinical efficacy of phakic implantable collamer lens(ICL)implantation in correcting low-to-moderate myopia.METHODS: Retrospective study. A total of 48 patients(85 eyes)with low to moderate myopia who underwent ICL implantation were included in the study. The changes in uncorrected visual acuity(LogMAR), corrected visual acuity(LogMAR), refractive outcomes, intraocular pressure, vault and endothelial cell were observed at 1 a postoperatively.RESULTS: At 12 mo postoperatively, uncorrected and best-corrected visual acuity were -0.10(-0.20, -0.10)and -0.10(-0.20, -0.10), respectively, with an efficacy index of 1.07±0.13 and a safe index of 1.10±0.14. The difference between the actual corrected diopter and the expected corrected diopter was 91%(77/85)in the range of ±0.50 D, and 100%(85/85)in the range of ±1.00 D. The mean vault was 501.16±210.46 μm at 12 mo postoperatively. There was no significant difference in corneal endothelial cell density between preoperative and 6 and 12 mo postoperatively(F=1.050, P=0.352). All patients had no anterior subcapsular opacification, cataract, pupillary block, or other sight threatening complications during follow-up.CONCLUSION: ICL implantation for the correction of low to moderate myopia has good efficacy, safety and predictability.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.3980/j.issn.1672-5123.2024.10.28
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phakic implantable collamer lens implantation for correcting low-to-moderate myopia

SHILAP Revista de lepidopterología
Corneal surgery and disorders
article

Phakic implantable collamer lens implantation for correcting low-to-moderate myopia

article en

Abstract

AIM:To investigate the clinical efficacy of phakic implantable collamer lens(ICL)implantation in correcting low-to-moderate myopia.METHODS: Retrospective study. A total of 48 patients(85 eyes)with low to moderate myopia who underwent ICL implantation were included in the study. The changes in uncorrected visual acuity(LogMAR), corrected visual acuity(LogMAR), refractive outcomes, intraocular pressure, vault and endothelial cell were observed at 1 a postoperatively.RESULTS: At 12 mo postoperatively, uncorrected and best-corrected visual acuity were -0.10(-0.20, -0.10)and -0.10(-0.20, -0.10), respectively, with an efficacy index of 1.07±0.13 and a safe index of 1.10±0.14. The difference between the actual corrected diopter and the expected corrected diopter was 91%(77/85)in the range of ±0.50 D, and 100%(85/85)in the range of ±1.00 D. The mean vault was 501.16±210.46 μm at 12 mo postoperatively. There was no significant difference in corneal endothelial cell density between preoperative and 6 and 12 mo postoperatively(F=1.050, P=0.352). All patients had no anterior subcapsular opacification, cataract, pupillary block, or other sight threatening complications during follow-up.CONCLUSION: ICL implantation for the correction of low to moderate myopia has good efficacy, safety and predictability.

SHILAP Revista de lepidopterología
Good health and well-being
Openalex Percentile: Top 52%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Phakic implantable collamer lens implantation for correcting low-to-moderate myopia · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS