Impact of concomitant aortic valve replacement in patients with mild-to-moderate aortic valve regurgitation undergoing left ventricular assist device implantation: EUROMACS analysis

IntroductionLeft ventricular assist device (LVAD) therapy may lead to an aortic regurgitation, limiting left ventricular unloading and causing adverse events. Whether concomitant aortic valve replacement may improve outcomes in patients with preoperative mild-to-moderate aortic regurgitation remains unclear.MethodsA retrospective propensity score-matched analysis of adult patients with preoperative mild-to-moderate aortic regurgitation undergoing durable LVAD implantation between 01/01/2011 and 30/11/2021 was performed. Patients undergoing concomitant valve surgery other than biological aortic valve replacement were excluded, resulting in 77 with concomitant biological aortic valve replacement and 385 without.ResultsFollowing 1:1 propensity score matching, two groups of 55 patients with and without biological aortic valve replacement were obtained, (mean age 59 +/- 11 years, 92% male, 59.1% HeartWare). Aortic regurgitation was mild in 72.7% and 76.4% and moderate in 27.3% and 23.6% in non-replacement and replacement cohorts respectively. The 30-day survival was 89.1% vs. 85.5% (p = 0.59), 1-year survival 69.1% vs. 56.4% (p = 0.19), and 2-year survival 61.8% vs. 47.3% (p = 0.10) in the non-replacement and replacement groups, respectively. After a mean follow-up of 1.2 years, non-replacement patients had a higher incidence of pump thrombosis (11 [20%] vs. 3 [5.5%], p = 0.022) and fewer major bleedings (2 [3.6%] vs. 11 [20%], p = 0.008).ConclusionCompared with those treated conservatively, patients with mild-to-moderate aortic regurgitation undergoing concomitant aortic valve replacement during LVAD implantation have a similar survival up to 2 years on support. Patients with concomitant valve replacement had a higher risk of bleeding complications but fewer pump thromboses.

Publication Details

Journal
Repository for Publications and Research Data (ETH Zurich)
Published
2025-04-01
DOI
https://doi.org/10.3929/ethz-b-000712195
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of concomitant aortic valve replacement in patients with mild-to-moderate aortic valve regurgitation undergoing left ventricular assist device implantation: EUROMACS analysis

Repository for Publications and Research Data (ETH Zurich)
Mechanical Circulatory Support Devices
article

Impact of concomitant aortic valve replacement in patients with mild-to-moderate aortic valve regurgitation undergoing left ventricular assist device implantation: EUROMACS analysis

article en

Abstract

IntroductionLeft ventricular assist device (LVAD) therapy may lead to an aortic regurgitation, limiting left ventricular unloading and causing adverse events. Whether concomitant aortic valve replacement may improve outcomes in patients with preoperative mild-to-moderate aortic regurgitation remains unclear.MethodsA retrospective propensity score-matched analysis of adult patients with preoperative mild-to-moderate aortic regurgitation undergoing durable LVAD implantation between 01/01/2011 and 30/11/2021 was performed. Patients undergoing concomitant valve surgery other than biological aortic valve replacement were excluded, resulting in 77 with concomitant biological aortic valve replacement and 385 without.ResultsFollowing 1:1 propensity score matching, two groups of 55 patients with and without biological aortic valve replacement were obtained, (mean age 59 +/- 11 years, 92% male, 59.1% HeartWare). Aortic regurgitation was mild in 72.7% and 76.4% and moderate in 27.3% and 23.6% in non-replacement and replacement cohorts respectively. The 30-day survival was 89.1% vs. 85.5% (p = 0.59), 1-year survival 69.1% vs. 56.4% (p = 0.19), and 2-year survival 61.8% vs. 47.3% (p = 0.10) in the non-replacement and replacement groups, respectively. After a mean follow-up of 1.2 years, non-replacement patients had a higher incidence of pump thrombosis (11 [20%] vs. 3 [5.5%], p = 0.022) and fewer major bleedings (2 [3.6%] vs. 11 [20%], p = 0.008).ConclusionCompared with those treated conservatively, patients with mild-to-moderate aortic regurgitation undergoing concomitant aortic valve replacement during LVAD implantation have a similar survival up to 2 years on support. Patients with concomitant valve replacement had a higher risk of bleeding complications but fewer pump thromboses.

Repository for Publications and Research Data (ETH Zurich)
Openalex Percentile: Top 57%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of concomitant aortic valve replacement in patients with mild-to-moderate aortic valve regurgitation undergoing left ventricular assist device implantation: EUROMACS analysis · Repository for Publications and Research Data (ETH Zurich) (2025) | TGRS Research Map | TGRS