Visual quality of patients with posterior capsular opacification after Nd:YAG laser surgery

AIM: To explore the value of the corneal/refractive analyzer OPD-Scan III in assessing visual quality after Nd:YAG laser surgery in patients with posterior capsular opacification.METHODS: A total of 98 patients(98 eyes)with posterior capsular opacification who underwent Nd:YAG laser posterior capsulotomy in our hospital from May 2021 to April 2023 were retrospectively selected as the research subjects, and higher-order aberration parameters(coma, spherical aberration and trefoil aberration)and visual quality parameters [Strehl ratio(SR)and 4 mm area ratio(AR)in the human eye modulation transfer function(MTF)curve] were obtained using the corneal/refractive analyzer OPD-Scan III. The patient's visual acuity, higher-order aberration parameters and visual quality before surgery, and at 1 wk and 3 mo after surgery were compared.RESULTS: There were statistically significant differences in uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA)and uncorrected near visual acuity(UNVA), coma, spherical aberration, trefoil aberration, SR and AR before and after surgery(all P<0.001), and there were statistically significant differences in UDVA, UIVA, UNVA, coma, spherical aberration, trefoil aberration, SR and AR at 1 wk and 3 mo postoperatively(all P<0.05). Additionally, there were differences in the UDVA, UIVA, UNVA, SR and AR at 3 mo postoperatively compared with those parameters at 1 wk postoperatively(all P<0.05), while there were no statistical significance in coma, spherical aberration, trefoil aberration at 3 mo postoperatively and those at 1 wk postoperatively(all P>0.05). Furthermore, the spherical aberration, trefoil aberration were negatively correlated with SR(rs=-0.427, P=0.009; rs=-0.436, P=0.010), and the trefoil aberration was negatively correlated with AR(rs=-0.406, P=0.015).CONCLUSION: The visual acuity of patients with posterior capsular opacification improved after Nd:YAG laser surgery, and the corneal/refractive analyzer OPD-Scan III system has a high clinical value in reflecting patient's visual quality.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.3980/j.issn.1672-5123.2024.10.25
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual quality of patients with posterior capsular opacification after Nd:YAG laser surgery

SHILAP Revista de lepidopterología
Intraocular Surgery and Lenses
article

Visual quality of patients with posterior capsular opacification after Nd:YAG laser surgery

article en

Abstract

AIM: To explore the value of the corneal/refractive analyzer OPD-Scan III in assessing visual quality after Nd:YAG laser surgery in patients with posterior capsular opacification.METHODS: A total of 98 patients(98 eyes)with posterior capsular opacification who underwent Nd:YAG laser posterior capsulotomy in our hospital from May 2021 to April 2023 were retrospectively selected as the research subjects, and higher-order aberration parameters(coma, spherical aberration and trefoil aberration)and visual quality parameters [Strehl ratio(SR)and 4 mm area ratio(AR)in the human eye modulation transfer function(MTF)curve] were obtained using the corneal/refractive analyzer OPD-Scan III. The patient's visual acuity, higher-order aberration parameters and visual quality before surgery, and at 1 wk and 3 mo after surgery were compared.RESULTS: There were statistically significant differences in uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA)and uncorrected near visual acuity(UNVA), coma, spherical aberration, trefoil aberration, SR and AR before and after surgery(all P<0.001), and there were statistically significant differences in UDVA, UIVA, UNVA, coma, spherical aberration, trefoil aberration, SR and AR at 1 wk and 3 mo postoperatively(all P<0.05). Additionally, there were differences in the UDVA, UIVA, UNVA, SR and AR at 3 mo postoperatively compared with those parameters at 1 wk postoperatively(all P<0.05), while there were no statistical significance in coma, spherical aberration, trefoil aberration at 3 mo postoperatively and those at 1 wk postoperatively(all P>0.05). Furthermore, the spherical aberration, trefoil aberration were negatively correlated with SR(rs=-0.427, P=0.009; rs=-0.436, P=0.010), and the trefoil aberration was negatively correlated with AR(rs=-0.406, P=0.015).CONCLUSION: The visual acuity of patients with posterior capsular opacification improved after Nd:YAG laser surgery, and the corneal/refractive analyzer OPD-Scan III system has a high clinical value in reflecting patient's visual quality.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 54%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visual quality of patients with posterior capsular opacification after Nd:YAG laser surgery · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS