Evaluation of Energy Efficiency and Optimization Measures at the Tanger Med Dam in the Fahs-Anjra Province (Morocco)

In the context of Morocco’s national energy strategy aiming to improve energy efficiency across public infrastructures, this study presents a detailed energy audit and optimization plan for the Tanger Med Dam, located in the province of Fahs-Anjra. The analysis covers three years of electrical consumption data (2019–2021) across two transformer substations (50 kVA and 100 kVA), in addition to associated lighting and electromechanical systems. The audit identified several inefficiencies, including oversized subscribed power, suboptimal power factor levels, and high energy consumption from conventional lighting systems. To address these issues, targeted actions were proposed, including the adjustment of subscribed power, the installation of reactive power compensation systems, and the replacement of lighting with LED and solar-powered technologies. The proposed measures demonstrate significant potential for reducing annual energy consumption by over 50%, lowering operational costs by more than 30%, and cutting CO₂ emissions by nearly 9 tonnes per year. The study provides a replicable framework for enhancing energy efficiency in hydraulic infrastructures, aligning with national sustainability goals.

Institutions

Publication Details

Journal
PRSM
Published
2025-05-17
DOI
https://doi.org/10.34874/prsm.ehei-jst-vol4iss2.57136
Primary Topic
Energy Efficiency and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Energy Efficiency and Optimization Measures at the Tanger Med Dam in the Fahs-Anjra Province (Morocco)

PRSM
Energy Efficiency and Management
article

Evaluation of Energy Efficiency and Optimization Measures at the Tanger Med Dam in the Fahs-Anjra Province (Morocco)

article en

Abstract

In the context of Morocco’s national energy strategy aiming to improve energy efficiency across public infrastructures, this study presents a detailed energy audit and optimization plan for the Tanger Med Dam, located in the province of Fahs-Anjra. The analysis covers three years of electrical consumption data (2019–2021) across two transformer substations (50 kVA and 100 kVA), in addition to associated lighting and electromechanical systems. The audit identified several inefficiencies, including oversized subscribed power, suboptimal power factor levels, and high energy consumption from conventional lighting systems. To address these issues, targeted actions were proposed, including the adjustment of subscribed power, the installation of reactive power compensation systems, and the replacement of lighting with LED and solar-powered technologies. The proposed measures demonstrate significant potential for reducing annual energy consumption by over 50%, lowering operational costs by more than 30%, and cutting CO₂ emissions by nearly 9 tonnes per year. The study provides a replicable framework for enhancing energy efficiency in hydraulic infrastructures, aligning with national sustainability goals.

PRSM
Abdelmalek Essaâdi University (MA), École des Hautes Études Commerciales (DZ)
Affordable and clean energy
Openalex Percentile: Top 68%
Energy Efficiency and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.