Effect of Slot Dimensions on Aligner Retention

Introduction: Orthodontic brackets with rectangular arch wire slots have been historically used for fixed orthodontic treatment and remain as the industry standard. In light of the biomechanical disadvantages of rectangular slot design and the tremendous market demand for clear aligner therapy, a novel orthodontic device system was designed and evaluated. Clear aligner therapy (CAT) as a solo system has another host of compromises and disadvantages which include lesser treatment outcomes and lack of tooth movement accuracy. A novel 3D printed orthodontic trapezoidal slot twin bracket was fabricated to be used as a fixed appliance, as a clear aligner system, and/or a combination of both. Research on this alternative slot form was conducted on aligner retention utilizing varying slot dimensions with the base of slot ranging from 0.014” to 0.018” and top of slot ranging from 0.040” to 0.060”. A 2mm retention attachment and no attachment model were used as an industry comparison/control. Methods: The trapezoidal slot twin bracket (UL5) was fabricated in composite/ceramic hybrid via 3D printed technology. The brackets were bonded to a 3D printed model and scanned using a Trios 3 intraoral scanner. The STL file was then 3D printed using Sprintray 3D printing technology. A vacuum-form using Zendura Flex aligner material was fabricated on the model using a Ministar S pressure forming machine. The aligner was trimmed equal-gingival. A custom uniaxial tensile testing machine was used to measure the force required to remove the aligner from the testing model. Results: The data collected was compared to each top of slot dimension (0.040”, 0.050”, 0.060”), each base of slot dimension (0.014” or 0.018”), no attachment, and 2mm retention attachment. Two-tailed T-tests showed clinical significance among all categories tested. An ANOVA was conducted to confirm clinical significance among the different slot configurations. Conclusion: From the data collected, researchers were able to select a slot dimension of choice for further testing of the system.

Publication Details

Journal
Digital Scholarship - UNLV (University of Nevada Reno)
Published
2024-10-02
DOI
https://doi.org/10.34917/37650820
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Slot Dimensions on Aligner Retention

Digital Scholarship - UNLV (University of Nevada Reno)
Orthodontics and Dentofacial Orthopedics
article

Effect of Slot Dimensions on Aligner Retention

article en

Abstract

Introduction: Orthodontic brackets with rectangular arch wire slots have been historically used for fixed orthodontic treatment and remain as the industry standard. In light of the biomechanical disadvantages of rectangular slot design and the tremendous market demand for clear aligner therapy, a novel orthodontic device system was designed and evaluated. Clear aligner therapy (CAT) as a solo system has another host of compromises and disadvantages which include lesser treatment outcomes and lack of tooth movement accuracy. A novel 3D printed orthodontic trapezoidal slot twin bracket was fabricated to be used as a fixed appliance, as a clear aligner system, and/or a combination of both. Research on this alternative slot form was conducted on aligner retention utilizing varying slot dimensions with the base of slot ranging from 0.014” to 0.018” and top of slot ranging from 0.040” to 0.060”. A 2mm retention attachment and no attachment model were used as an industry comparison/control. Methods: The trapezoidal slot twin bracket (UL5) was fabricated in composite/ceramic hybrid via 3D printed technology. The brackets were bonded to a 3D printed model and scanned using a Trios 3 intraoral scanner. The STL file was then 3D printed using Sprintray 3D printing technology. A vacuum-form using Zendura Flex aligner material was fabricated on the model using a Ministar S pressure forming machine. The aligner was trimmed equal-gingival. A custom uniaxial tensile testing machine was used to measure the force required to remove the aligner from the testing model. Results: The data collected was compared to each top of slot dimension (0.040”, 0.050”, 0.060”), each base of slot dimension (0.014” or 0.018”), no attachment, and 2mm retention attachment. Two-tailed T-tests showed clinical significance among all categories tested. An ANOVA was conducted to confirm clinical significance among the different slot configurations. Conclusion: From the data collected, researchers were able to select a slot dimension of choice for further testing of the system.

Digital Scholarship - UNLV (University of Nevada Reno)
Industry, innovation and infrastructure
Openalex Percentile: Top 64%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Slot Dimensions on Aligner Retention · Digital Scholarship - UNLV (University of Nevada Reno) (2024) | TGRS Research Map | TGRS