The Effect of Sonification Pulse Rate and System Reliability on Perceived Workload Urgency Trust and Monitoring Performance

The purpose of the current study was to examine the effect of sonification pulse rate and system reliability on subjective workload, urgency, trust, and monitoring performance of a dual task simulation of patient monitoring. Fifty-eight students performed a compensatory tracking and resource management task while simultaneously engaging in a patient monitoring task. Sonification pulse rate contained three levels (40ppm, 60ppm, 80ppm) and was manipulated within groups by varying the inter-pulse interval of the auditory signal. System reliability contained two levels (40%, 60%) and was manipulated between groups by varying the number of true and false problems presented by the sonification system. Perceived subjective workload, trust, and urgency were examined via questionnaires. Monitoring performance accuracy was examined using two models of SignaI Detection Theory (SDT). A series of 2 x 3 Mixed ANOVA's were used to analyze subjective and performance data. Results mainly supported our hypotheses. Specifically, results demonstrate significant effects of pulse rate and reliability on subjective workload, trust, urgency, and monitoring performance. Overall, setting the sonification to 60 ppm relative to 40ppm and 80ppm resulted in lower workload ratings, higher trust ratings, and moderate urgency ratings. Furthermore, participants made timely responses and increased decision accuracy, without increasing reaction responsiveness, when the sonification pulse rate was set to 60 ppm. These results are important for sonification design, and suggest that setting sonification pulse rate to 60 ppm can maximize monitoring accuracy without overburdening the operator. Areas of future research and practical applications are discussed.

Institutions

Publication Details

Journal
ODU Digital Commons (Old Dominion University)
Published
2024-12-05
DOI
https://doi.org/10.25777/3v43-9x58
Primary Topic
Tactile and Sensory Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Sonification Pulse Rate and System Reliability on Perceived Workload Urgency Trust and Monitoring Performance

ODU Digital Commons (Old Dominion University)
Tactile and Sensory Interactions
article

The Effect of Sonification Pulse Rate and System Reliability on Perceived Workload Urgency Trust and Monitoring Performance

article en

Abstract

The purpose of the current study was to examine the effect of sonification pulse rate and system reliability on subjective workload, urgency, trust, and monitoring performance of a dual task simulation of patient monitoring. Fifty-eight students performed a compensatory tracking and resource management task while simultaneously engaging in a patient monitoring task. Sonification pulse rate contained three levels (40ppm, 60ppm, 80ppm) and was manipulated within groups by varying the inter-pulse interval of the auditory signal. System reliability contained two levels (40%, 60%) and was manipulated between groups by varying the number of true and false problems presented by the sonification system. Perceived subjective workload, trust, and urgency were examined via questionnaires. Monitoring performance accuracy was examined using two models of SignaI Detection Theory (SDT). A series of 2 x 3 Mixed ANOVA's were used to analyze subjective and performance data. Results mainly supported our hypotheses. Specifically, results demonstrate significant effects of pulse rate and reliability on subjective workload, trust, urgency, and monitoring performance. Overall, setting the sonification to 60 ppm relative to 40ppm and 80ppm resulted in lower workload ratings, higher trust ratings, and moderate urgency ratings. Furthermore, participants made timely responses and increased decision accuracy, without increasing reaction responsiveness, when the sonification pulse rate was set to 60 ppm. These results are important for sonification design, and suggest that setting sonification pulse rate to 60 ppm can maximize monitoring accuracy without overburdening the operator. Areas of future research and practical applications are discussed.

ODU Digital Commons (Old Dominion University)
Dominion University College (GH), Old Dominion University (US)
Openalex Percentile: Top 65%
Tactile and Sensory Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effect of Sonification Pulse Rate and System Reliability on Perceived Workload Urgency Trust and Monitoring Performance · ODU Digital Commons (Old Dominion University) (2024) | TGRS Research Map | TGRS