Theoretical Study of Energy Loss of Proton in Human Tissues

In this paper, a theoretical study was carried out to calculate the proton energy loss in human tissues (Adipose tissue, Blood, Bone (Compact), Bone (Cortical), Brain, Eye lens, Lung, Skin, and Testicles) within the energy range of 1 MeV to 1000 MeV. We calculated the total stopping power for each tissue element separately using the Bethe-Bloch equation, and then used Bragg's rule for compounds to determine the tissue's total stopping power. The total stopping power is directly proportional to the atomic number divided by the target material's atomic mass (Z/A) and target material density (ρ), and inversely proportional to the target material's mean excitation energy (I) and proton energy (E). The results indicate that the stopping power was highest in the adipose tissue, and the lowest value was in the bone (cortical) at the same proton energy. We performed all calculations using the MATLAB program. We found a good match between the obtained results and the value of the P-Star code.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.30526/37.4.3636
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theoretical Study of Energy Loss of Proton in Human Tissues

SHILAP Revista de lepidopterología
Radiation Therapy and Dosimetry
article

Theoretical Study of Energy Loss of Proton in Human Tissues

article en

Abstract

In this paper, a theoretical study was carried out to calculate the proton energy loss in human tissues (Adipose tissue, Blood, Bone (Compact), Bone (Cortical), Brain, Eye lens, Lung, Skin, and Testicles) within the energy range of 1 MeV to 1000 MeV. We calculated the total stopping power for each tissue element separately using the Bethe-Bloch equation, and then used Bragg's rule for compounds to determine the tissue's total stopping power. The total stopping power is directly proportional to the atomic number divided by the target material's atomic mass (Z/A) and target material density (ρ), and inversely proportional to the target material's mean excitation energy (I) and proton energy (E). The results indicate that the stopping power was highest in the adipose tissue, and the lowest value was in the bone (cortical) at the same proton energy. We performed all calculations using the MATLAB program. We found a good match between the obtained results and the value of the P-Star code.

SHILAP Revista de lepidopterología
Salahaddin University-Erbil (IQ)
Affordable and clean energy
Openalex Percentile: Top 51%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Theoretical Study of Energy Loss of Proton in Human Tissues · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS