Detection of thickness changes in compressed battery cells
An apparatus and method for non-contact and spatially resolved measurement of thickness changes in compressed flat lithium-ion battery cells during cycling is presented. This approach can be applied to end-of-line quality control in manufacturing battery cells. The large amount of measured data generated is used in machine-learning models to quickly and unambiguously evaluate the quality of the battery cell.
Publication Details
- Journal
- Fraunhofer-Publica (Fraunhofer-Gesellschaft)
- Published
- 2024-10-25
- DOI
- https://doi.org/10.24406/h-477980
- Primary Topic
- Advanced Battery Technologies Research
- Type
- article
- Field-Weighted Citation Impact
- 0.00