Aerodynamic Test of AGARD-B Model at Mach 10 in Arc-heated High-Enthalpy Wind Tunnel

The test capacity of hypersonic equipment is crucial to the development of hypersonic technology. However, the maximum Mach number simulated by conventional hypersonic wind tunnel is less than 10 currently due to the insufficient heater capacity. Considering the outstanding performance of arc heater in high-enthalpy wind tunnel, applying arc-heated high-enthalpy wind tunnel for conventional aerodynamic tests makes a breakthrough for increasing test Mach numbers. This paper presented the test of AGARD-B calibration model carried out in the arc-heated high-enthalpy wind tunnel of the China Academy of Aerospace Aerodynamics. The standard deviation of multiple repeated aerodynamic test results verified the self-consistency of test data and proved the stability of flow field. Accuracy of the test data was also certified through comparison and analysis with existing data from both foreign and domestic wind tunnels. This test demonstrated that the arc-heated high-enthalpy wind tunnel is fully capable of conducting aerodynamic tests at Mach 10.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.19527/j.cnki.2096-1642.1093
Primary Topic
Gas Dynamics and Kinetic Theory
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aerodynamic Test of AGARD-B Model at Mach 10 in Arc-heated High-Enthalpy Wind Tunnel

SHILAP Revista de lepidopterología
Gas Dynamics and Kinetic Theory
article

Aerodynamic Test of AGARD-B Model at Mach 10 in Arc-heated High-Enthalpy Wind Tunnel

article en

Abstract

The test capacity of hypersonic equipment is crucial to the development of hypersonic technology. However, the maximum Mach number simulated by conventional hypersonic wind tunnel is less than 10 currently due to the insufficient heater capacity. Considering the outstanding performance of arc heater in high-enthalpy wind tunnel, applying arc-heated high-enthalpy wind tunnel for conventional aerodynamic tests makes a breakthrough for increasing test Mach numbers. This paper presented the test of AGARD-B calibration model carried out in the arc-heated high-enthalpy wind tunnel of the China Academy of Aerospace Aerodynamics. The standard deviation of multiple repeated aerodynamic test results verified the self-consistency of test data and proved the stability of flow field. Accuracy of the test data was also certified through comparison and analysis with existing data from both foreign and domestic wind tunnels. This test demonstrated that the arc-heated high-enthalpy wind tunnel is fully capable of conducting aerodynamic tests at Mach 10.

SHILAP Revista de lepidopterología
China Aerodynamics Research and Development Center (CN)
Affordable and clean energy
Openalex Percentile: Top 46%
Gas Dynamics and Kinetic Theory
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.