Remote intelligent test method and application of relay protection of smart substation based on autonomous controllable technology

Aiming at the problems that the verification time of relay protection devices in smart substations is much longer than the planned power outage time, the workload of verification is large, and the training period of related technical personnel is long, this paper designs a remote intelligent test method for relay protection of smart substations based on autonomous controllable technology. The overall architecture and network architecture of the system are given. Without changing the original network and configuration in the station, one or more dedicated in-station test terminals are deployed to access the process layer and station control layer. The DL/T 860 protocol rules, complex event processing algorithms and alarm correlation analysis engine mechanism process the alarm information generated during the action of relay protection, and propose the remote intelligent simulation test process of relay protection, "one-click" protection simulation test technology and the remote testing technology and method of protection configuring parameters. The correctness of sampling and the integrity of the secondary circuit are verified by using the remote intelligent test method of relay protection of smart substation.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.19753/j.issn1001-1390.2025.05.022
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Remote intelligent test method and application of relay protection of smart substation based on autonomous controllable technology

SHILAP Revista de lepidopterología
Power Systems Fault Detection
article

Remote intelligent test method and application of relay protection of smart substation based on autonomous controllable technology

article en

Abstract

Aiming at the problems that the verification time of relay protection devices in smart substations is much longer than the planned power outage time, the workload of verification is large, and the training period of related technical personnel is long, this paper designs a remote intelligent test method for relay protection of smart substations based on autonomous controllable technology. The overall architecture and network architecture of the system are given. Without changing the original network and configuration in the station, one or more dedicated in-station test terminals are deployed to access the process layer and station control layer. The DL/T 860 protocol rules, complex event processing algorithms and alarm correlation analysis engine mechanism process the alarm information generated during the action of relay protection, and propose the remote intelligent simulation test process of relay protection, "one-click" protection simulation test technology and the remote testing technology and method of protection configuring parameters. The correctness of sampling and the integrity of the secondary circuit are verified by using the remote intelligent test method of relay protection of smart substation.

SHILAP Revista de lepidopterología
State Grid Corporation of China (China) (CN)
Openalex Percentile: Top 48%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.