The Jena S-EBIT facility

EBITs are versatile tools for spectroscopic studies of partially ionized atomic systems, mainly in the x-ray domain. This yields valuable information for fundamental atomic physics as well as astrophysics. Ion charge state distributions, resulting from ionization and recombination processes, can be observed and used to benchmark plasma dynamics. Furthermore, EBITs can be used as small stand-alone ion sources, as they are already used for example at the HITRAP facility. The Jena S-EBIT facility are two EBITs, the former R- and S-EBIT from Stockholm*, which both are suitable for x-ray spectroscopy studies and ion extraction. The S-EBIT I has been used as a tool for x-ray spectroscopy, including the testing of newly developed x-ray detectors, like the magnetic metallic microcalorimeter maXs30**. In addition, the setup was expanded by a testing beamline, to evaluate the potential of the S-EBIT I as an ion source. The S-EBIT II is currently in commissioning for operation as a standalone ion source for HITRAP in the near future. This will provide new opportunities for local experiments, like the ARTEMIS experiment, independently from the GSI accelerator infrastructure.

Publication Details

Journal
JACOW
Published
2025-05-06
DOI
https://doi.org/10.18429/jacow-ebist2022-we3wh03
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Jena S-EBIT facility

JACOW
X-ray Spectroscopy and Fluorescence Analysis
article

The Jena S-EBIT facility

article en

Abstract

EBITs are versatile tools for spectroscopic studies of partially ionized atomic systems, mainly in the x-ray domain. This yields valuable information for fundamental atomic physics as well as astrophysics. Ion charge state distributions, resulting from ionization and recombination processes, can be observed and used to benchmark plasma dynamics. Furthermore, EBITs can be used as small stand-alone ion sources, as they are already used for example at the HITRAP facility. The Jena S-EBIT facility are two EBITs, the former R- and S-EBIT from Stockholm*, which both are suitable for x-ray spectroscopy studies and ion extraction. The S-EBIT I has been used as a tool for x-ray spectroscopy, including the testing of newly developed x-ray detectors, like the magnetic metallic microcalorimeter maXs30**. In addition, the setup was expanded by a testing beamline, to evaluate the potential of the S-EBIT I as an ion source. The S-EBIT II is currently in commissioning for operation as a standalone ion source for HITRAP in the near future. This will provide new opportunities for local experiments, like the ARTEMIS experiment, independently from the GSI accelerator infrastructure.

JACOW
Industry, innovation and infrastructure
Openalex Percentile: Top 46%
X-ray Spectroscopy and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.