Cavity Beam Position Monitors pulse Injection source
The Cavity Beam Position Monitor (CBPM) system at Accelerator Test Facil- ity 2 (ATF2, KEK, Japan) operates with attenuation at a reduced 200 nm (vs measured 20-30 nm) resolution to cope with CBPM to magnet misalignment. In addition, CBPMs need regular calibrations to maintain their performance. To address these limitations, a pulse injection system is under development. This system aims to compensate for static offsets by injecting an anti-phase replica of the average beam signal directly into the sensor cavities. The same signal can provide a calibration tone for the whole processing chain and eliminate lengthy beam-based calibrations. Proof of principle tests for such a system have been conducted in December 2023. In this paper, we report on the results of the first beam test, discuss the technical challenges and provide a preliminary hardware specification for future experiments.
Publication Details
- Journal
- JACOW
- Published
- 2024-12-18
- DOI
- https://doi.org/10.18429/jacow-ibic2024-tup17
- Primary Topic
- Particle Accelerators and Free-Electron Lasers
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Science and Technology Facilities Council