Cavity Beam Position Monitors pulse Injection source

The Cavity Beam Position Monitor (CBPM) system at Accelerator Test Facil- ity 2 (ATF2, KEK, Japan) operates with attenuation at a reduced 200 nm (vs measured 20-30 nm) resolution to cope with CBPM to magnet misalignment. In addition, CBPMs need regular calibrations to maintain their performance. To address these limitations, a pulse injection system is under development. This system aims to compensate for static offsets by injecting an anti-phase replica of the average beam signal directly into the sensor cavities. The same signal can provide a calibration tone for the whole processing chain and eliminate lengthy beam-based calibrations. Proof of principle tests for such a system have been conducted in December 2023. In this paper, we report on the results of the first beam test, discuss the technical challenges and provide a preliminary hardware specification for future experiments.

Publication Details

Journal
JACOW
Published
2024-12-18
DOI
https://doi.org/10.18429/jacow-ibic2024-tup17
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cavity Beam Position Monitors pulse Injection source

JACOW
Particle Accelerators and Free-Electron Lasers
article

Cavity Beam Position Monitors pulse Injection source

article en

Abstract

The Cavity Beam Position Monitor (CBPM) system at Accelerator Test Facil- ity 2 (ATF2, KEK, Japan) operates with attenuation at a reduced 200 nm (vs measured 20-30 nm) resolution to cope with CBPM to magnet misalignment. In addition, CBPMs need regular calibrations to maintain their performance. To address these limitations, a pulse injection system is under development. This system aims to compensate for static offsets by injecting an anti-phase replica of the average beam signal directly into the sensor cavities. The same signal can provide a calibration tone for the whole processing chain and eliminate lengthy beam-based calibrations. Proof of principle tests for such a system have been conducted in December 2023. In this paper, we report on the results of the first beam test, discuss the technical challenges and provide a preliminary hardware specification for future experiments.

JACOW
Science and Technology Facilities Council
Affordable and clean energy
Openalex Percentile: Top 68%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.